Combined Synopsis/SolicitationPosted Aug 10, 2026·Responses due Aug 21, 2026

6515--Combined Synopsis RFQ: Portable Reverse Osmosis Water Purification System for the James J. Peters VAMC.

Veterans Affairs · 242-NETWORK CONTRACT OFFICE 02 (36C242)

Stage
Open solicitation
NAICS
334516
Value
Not stated
Solicitation
36C24226Q0795
Set-aside
None stated
PSC
6515
Place
Bronx
Contact
Rondon, Jonatan (jonatan.rondon@va.gov)
Loading your pipeline and notes…
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation 36C24226Q0795 in this department, oldest first.

Early notice
  • Jul 14, 2026
    Sources Sought
    Open
Solicitation
  • Aug 10, 2026 · this notice
    Combined Synopsis/Solicitation
Award
Not yet. Typical award: Aug 26, 2026 to Sep 26, 2026, middle of the range Sep 6, 2026.
Measured from 97 past solicitations at Veterans Affairs, Department of with NAICS 334516 that later posted an award (middle half of cases, counted from Aug 10, 2026).

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Decide bid or no bid before the response deadline.
  • Look at the past winners for likely competitors and teaming partners.
  • Follow the opportunity to hear about amendments and the award.

What the notice says

Description This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format Revolutionary FAR Overhaul (RFO) in Federal Acquisition Regulation (FAR) subpart 12.202, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued. This solicitation is issued as an RFQ. The solicitation docum… (show all)

ent and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, effective date 03/13/2026. This solicitation is unrestricted. The associated North American Industrial Classification System (NAICS) code for this procurement is 334516, with a small business size standard of 1,000 employees. The FSC/PSC is 6515. The James J. Peters VA Medical Center is seeking to purchase four (4) AquaC 20 Amp Portable Reverse Osmosis Systems. All interested companies shall provide quotations for the following: Four (4) AquaC 20 Amp Portable Reverse Osmosis Systems (Product No. 24-0970-1) Four (4) AAMI Water Profile Kits (Product No. 24-AAMI-0) One (1) AquaC System Tech Training at Training Center One (1) AquaC C Uno RO Install with Mar Cor Cart The contractor shall provide complete installation of all four (4) AquaC RO units, including mounting on existing Mar Cor carts, plumbing connections, and system commissioning. The contractor shall provide on-site or training-center technical training for Medical Center clinical staff in accordance with the following parameters: Service: AquaC System Tech Training at Training Center (Product No. 111122) Initial training shall consist of a minimum of twenty-four (24) hours, not to exceed forty (40) hours, for up to five (5) healthcare professionals. One (1) follow-up training session is included within the contract price. Training must be initiated within thirty (30) calendar days after system installation; the follow-up training must be initiated within ninety (90) calendar days after installation. Failure to initiate within these windows shall result in expiration of included training, and additional fees will apply. Additional attendees beyond five (5) and any additional training beyond initial plus one follow-up session are not included in this SOW and will incur additional charges. AquaC Salient Characteristics: System Type Portable, single-patient reverse osmosis (RO) water purification system Configuration Modular cart-mounted unit; compact design for bedside/in-unit placement Height 500 mm (1.64 ft) unit only, excluding cart Width 520 mm (1.71 ft) Depth 195 mm (0.64 ft) Weight (Empty) Approximately 35 kg (77.2 lb) Weight (Full) Approximately 37.5 kg (82.7 lb) Cart Compatibility Must be compatible with Marcor cart platform; designed for mounting on AquaC Cart US option Portability Must be cart-mounted and portable within the clinical environment; no permanent plumbing required Water Quality Standard Must meet or exceed ANSI/AAMI RD52 hemodialysis water quality standards for bacteria, endotoxins, and chemical contaminants Permeate Output Minimum 85 L/h (±10%) at 15°C (59°F) water inlet temperature Bacterial / Endotoxin Rejection Greater than 99% rejection rate for bacteria and endotoxins Dissolved Salt Rejection Greater than 96% average rejection rate for dissolved salts Membrane Type Spirally-wound RO membrane Yield (Low Hardness) Up to 70% at feed water hardness <1 °dH (<17.8 ppm CaCO3) Yield (Higher Hardness) Up to 60% at feed water hardness >1 °dH (>17.8 ppm CaCO3) Concentrate Pressure (Max) Maximum 290.1 psi Noise Level (SUPPLY mode) 44 46 dB(A) measured at 1 meter distance Permeate Output (Disinfection) 12 L/h (±10%) during ring heat disinfection cycle Bacterial / Endotoxin Rejection Greater than 99% rejection rate for bacteria and endotoxins Dissolved Salt Rejection Greater than 96% average rejection rate for dissolved salts Membrane Type Spirally-wound RO membrane Yield (Low Hardness) Up to 70% at feed water hardness <1 °dH (<17.8 ppm CaCO3) Yield (Higher Hardness) Up to 60% at feed water hardness >1 °dH (>17.8 ppm CaCO3) Concentrate Pressure (Max) Maximum 290.1 psi Noise Level (SUPPLY mode) 44 46 dB(A) measured at 1 meter distance Permeate Output (Disinfection) 12 L/h (±10%) during ring heat disinfection cycle Bacterial / Endotoxin Rejection Greater than 99% rejection rate for bacteria and endotoxins Dissolved Salt Rejection Greater than 96% average rejection rate for dissolved salts Membrane Type Spirally-wound RO membrane Yield (Low Hardness) Up to 70% at feed water hardness <1 °dH (<17.8 ppm CaCO3) Yield (Higher Hardness) Up to 60% at feed water hardness >1 °dH (>17.8 ppm CaCO3) Concentrate Pressure (Max) Maximum 290.1 psi Noise Level (SUPPLY mode) 44 46 dB(A) measured at 1 meter distance Permeate Output (Disinfection) 12 L/h (±10%) during ring heat disinfection cycle Electrical Supply 120 V AC, 60 Hz, 20 Amp dedicated circuit Nominal Power Variants 120 V 1000 VA or 120 V 1700 VA (per voltage variant) Operating Mode Continuous operation (Standby); SUPPLY mode used periodically during treatment Electrical Safety Classification Classified per EN 60601-1:2006 + A1:2013 / IEC 60601-1:2005 + A1:2012 Grounding Requirement Must be connected to supply network with protective conductor (grounded outlet); no ungrounded connections permitted Fuse Protection Internal fuses for voltage component protection; replaceable only by trained/certified personnel EMC Compliance Compliant with applicable electromagnetic compatibility (EMC) standards; no stacked installation with other electrical devices Interface / Connectivity Fresenius hemodialysis device interface port; LAN port (RJ-45); compatible with Fresenius 2008T BlueStar dialysis machines Thermal Disinfection Module Module heat disinfection up to 82°C (179.6°F) Thermal Disinfection Ring Ring heat disinfection up to 90°C (194°F) Membrane Service Life Minimum expected life of 120 heat disinfection cycles Chemical Disinfection Compatible with peracetic acid solution (~0.2% effective concentration); system volume 2.5 L (0.66 gal) Decalcification Compatible with approximately 20% citric acid solution; automated decalcification program required Rinse Interval Automated rinse cycle: minimum every 4 hours; rinse volume 10 L (3 gal) or 10-minute rinse time AutoSTART / AutoSTOP System shall support automatic start in SUPPLY mode via communication cable connection to dialysis machine Disinfection Validation System must provide auditable disinfection reporting and daily operational data acquisition logs Biocompatibility Standard All components in contact with permeate must be biocompatible per DIN EN ISO 10993-1 Tubing / Piping Material FEP, silicone, or stainless steel; food-grade with chemical resistance Sensors Titanium (Ti), Aluminum Oxide (Al O ), PBT Module Tube V4A stainless steel Membrane Material PSU/PA (polysulfone/polyamide) Hydraulic Blocks / Valves iPP, PVDF, Noryl GTX Seals EPDM (ethylene propylene diene monomer) Sampling Ports Integrated permeate sampling ports for microbiological and chemical analysis Permeate Connection Permeate nipple; optional permeate coupling; compatible with Fresenius hemodialysis machine water inlet Feed / Concentrate Flow Feed flow: 0.0 20 L/min (±10%); Concentrate flow: 0.0 20 L/min (±10%) Permeate Consumption 0 6 L/min (±10%) during normal supply operation Drain Connection System drain must connect to available outlet; no recontamination of permeate circuit permitted Water Supply Hose Must connect to potable water supply meeting pre-treatment feed water requirements Installation Type Portable; no permanent wall or floor mounting required; Marcor cart-based Stacking / Adjacency System must NOT be stacked with other electrical devices; minimum separation distances from radiation sources required per IFU Operati

Who won similar work

48 award notices on SAM.gov in the last 24 months. Matched by: Same office (242-NETWORK CONTRACT OFFICE 02 (36C242)), same product/service code (PSC) 6515.

Single-winner award sizes (48): middle half $68K to $614K, median $287K; range $15K to $3.2M.

WinnerAwardsValueLast
SDV OFFICE SYSTEMS LLC5$12.3MApr 8, 2026
BEACON POINT ASSOCIATES LLC3$1.8MAug 5, 2026
FOUR POINTS TECHNOLOGY, L.L.C.3$1.5MSep 10, 2025
Trillamed LLC3$1.5MApr 10, 2026
GEO-MED, LLC2$975KAug 25, 2026
HILL-ROM, INC.2$566KOct 1, 2026
SCRIPTPRO USA INC2$234KMar 13, 2026
Sierra7, Inc.1$1.3MAug 14, 2026
STANDARD COMMUNICATIONS INC1$1.2MAug 18, 2026
AFTER ACTION MEDICAL AND DENTAL SUPPLY, LLC1$725KAug 12, 2026

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in. Revenue next to a ticker is the company's last annual revenue from its 10-K.

Latest awards

Materiality: one award's value as a share of the winner's revenue over the latest 12 months in its SEC filings (or its last fiscal year, as noted when you point at it). Low under 1%, Medium 1 to 5%, High 5% or more. Many awards are paid over several years, so this overstates a single year's share.

Competitive landscape

For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 0 of these past winners lobbied Veterans Affairs, Dept of (VA) since 2024 (0 filings)
  • 0 of their lobbyists list a past Veterans Affairs, Dept of (VA) job
  • No corporate PAC money from them to the overseeing committees since 2024
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 0 bills named on the past winners' lobbying filings
  • 25 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.

  • 0 of the past winners are listed companies
  • 0 insider buys and 0 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.