Sources SoughtPosted Jul 14, 2026·Responses due Jul 27, 2026

6515--Sources Sought: Portable Reverse Osmosis Water Purification System.

Veterans Affairs · 242-NETWORK CONTRACT OFFICE 02 (36C242)

Stage
Early notice (sources sought, presolicitation or special notice)
NAICS
334516
Value
Not stated
Solicitation
36C24226Q0795
Set-aside
None stated
PSC
6515
Place
Bronx
Contact
Jonatan Rondon (jonatan.rondon@va.gov)
Loading your pipeline and notes…
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation 36C24226Q0795 in this department, oldest first.

Early notice
  • Jul 14, 2026 · this notice
    Sources Sought
Solicitation
  • Aug 10, 2026
    Combined Synopsis/Solicitation
    Open
Award
Not yet. Typical award: Aug 3, 2026 to Oct 1, 2026, middle of the range Aug 29, 2026.
Measured from 103 past early notices at Veterans Affairs, Department of with NAICS 334516 that later posted an award (middle half of cases, counted from Jul 14, 2026).

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Answer the notice: this is when the requirement can still be shaped.
  • Contact the contracting officer named on the notice.
  • Check who won similar work; they are the likely bidders.

What the notice says

THIS REQUEST IS FOR SOURCES SOUGHT AND IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS SOURCES SOUGHT NOTICE IN ACCORDANCE WITH (IAW) FAR 15.201(e). DISCLAIMER This Sources Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this Sources Sought Notice is marked as proprietary and will be handled accordingly. … (show all)

IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this Sources Sought Notice. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a Sources Sought Notice only. The purpose of this Sources Sought Notice is to gain knowledge of potential qualified sources and their size classification relative to NAICS code 334516 (size standard of 1,000 employees). Responses to this Sources Sought Notice will be used by the Government to make appropriate acquisition decisions. After review of the responses to this Sources Sought Notice, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide the Portable Reverse Osmosis Water Purification System, or a non-brand equivalent that at a minimum meets the following salient characteristics for the VA James J. Peters VAMC: The VA has a domestic preference for items manufactured in the United States. The VA requires for the one-time procurement of four (4) AquaC 20 Amp portable reverse osmosis (RO) water purification systems with AAMI Water Profile Kit, or equivalent to. The systems are required to support hemodialysis operations and to ensure a safe, AAMI-compliant water supply for patient care. The current portables require immediate replacement due to frequent, high-level bacterial contamination. Despite rigorous, in-depth disinfection and ongoing maintenance, the units advanced age and deterioration prevent effective sanitization. Scope: Purchase of AquaC UNO RO 20 amp water purification system which includes equipment installation and training. Specific Tasks The contractor shall furnish and deliver the following equipment: Four (4) AquaC 20 Amp Portable Reverse Osmosis Systems (Product No. 24-0970-1) Four (4) AAMI Water Profile Kits (Product No. 24-AAMI-0) The contractor shall provide complete installation of all four (4) AquaC RO units, including mounting on existing Marcor carts, plumbing connections, and system commissioning. The contractor shall provide on-site or training-center technical training for Medical Center clinical staff in accordance with the following parameters: Service: AquaC System Tech Training at Training Center (Product No. 111122) Initial training shall consist of a minimum of twenty-four (24) hours, not to exceed forty (40) hours, for up to five (5) healthcare professionals. One (1) follow-up training session is included within the contract price. Training must be initiated within thirty (30) calendar days after system installation; the follow-up training must be initiated within ninety (90) calendar days after installation. Failure to initiate within these windows shall result in expiration of included training, and additional fees will apply. Additional attendees beyond five (5) and any additional training beyond initial plus one follow-up session are not included in this SOW and will incur additional charges. AquaC Salient Characteristics: System Type Portable, single-patient reverse osmosis (RO) water purification system Configuration Modular cart-mounted unit; compact design for bedside/in-unit placement Height 500 mm (1.64 ft) unit only, excluding cart Width 520 mm (1.71 ft) Depth 195 mm (0.64 ft) Weight (Empty) Approximately 35 kg (77.2 lb) Weight (Full) Approximately 37.5 kg (82.7 lb) Cart Compatibility Must be compatible with Marcor cart platform; designed for mounting on AquaC Cart US option Portability Must be cart-mounted and portable within the clinical environment; no permanent plumbing required Water Quality Standard Must meet or exceed ANSI/AAMI RD52 hemodialysis water quality standards for bacteria, endotoxins, and chemical contaminants Permeate Output Minimum 85 L/h (±10%) at 15°C (59°F) water inlet temperature Bacterial / Endotoxin Rejection Greater than 99% rejection rate for bacteria and endotoxins Dissolved Salt Rejection Greater than 96% average rejection rate for dissolved salts Membrane Type Spirally-wound RO membrane Yield (Low Hardness) Up to 70% at feed water hardness <1 °dH (<17.8 ppm CaCO3) Yield (Higher Hardness) Up to 60% at feed water hardness >1 °dH (>17.8 ppm CaCO3) Concentrate Pressure (Max) Maximum 290.1 psi Noise Level (SUPPLY mode) 44 46 dB(A) measured at 1 meter distance Permeate Output (Disinfection) 12 L/h (±10%) during ring heat disinfection cycle Bacterial / Endotoxin Rejection Greater than 99% rejection rate for bacteria and endotoxins Dissolved Salt Rejection Greater than 96% average rejection rate for dissolved salts Membrane Type Spirally-wound RO membrane Yield (Low Hardness) Up to 70% at feed water hardness <1 °dH (<17.8 ppm CaCO3) Yield (Higher Hardness) Up to 60% at feed water hardness >1 °dH (>17.8 ppm CaCO3) Concentrate Pressure (Max) Maximum 290.1 psi Noise Level (SUPPLY mode) 44 46 dB(A) measured at 1 meter distance Permeate Output (Disinfection) 12 L/h (±10%) during ring heat disinfection cycle Bacterial / Endotoxin Rejection Greater than 99% rejection rate for bacteria and endotoxins Dissolved Salt Rejection Greater than 96% average rejection rate for dissolved salts Membrane Type Spirally-wound RO membrane Yield (Low Hardness) Up to 70% at feed water hardness <1 °dH (<17.8 ppm CaCO3) Yield (Higher Hardness) Up to 60% at feed water hardness >1 °dH (>17.8 ppm CaCO3) Concentrate Pressure (Max) Maximum 290.1 psi Noise Level (SUPPLY mode) 44 46 dB(A) measured at 1 meter distance Permeate Output (Disinfection) 12 L/h (±10%) during ring heat disinfection cycle Electrical Supply 120 V AC, 60 Hz, 20 Amp dedicated circuit Nominal Power Variants 120 V 1000 VA or 120 V 1700 VA (per voltage variant) Operating Mode Continuous operation (Standby); SUPPLY mode used periodically during treatment Electrical Safety Classification Classified per EN 60601-1:2006 + A1:2013 / IEC 60601-1:2005 + A1:2012 Grounding Requirement Must be connected to supply network with protective conductor (grounded outlet); no ungrounded connections permitted Fuse Protection Internal fuses for voltage component protection; replaceable only by trained/certified personnel EMC Compliance Compliant with applicable electromagnetic compatibility (EMC) standards; no stacked installation with other electrical devices Interface / Connectivity Fresenius hemodialysis device interface port; LAN port (RJ-45); compatible with Fresenius 2008T BlueStar dialysis machines Thermal Disinfection Module Module heat disinfection up to 82°C (179.6°F) Thermal Disinfection Ring Ring heat disinfection up to 90°C (194°F) Membrane Service Life Minimum expected life of 120 heat disinfection cycles Chemical Disinfection Compatible with peracetic acid solution (~0.2% effective concentration); system volume 2.5 L (0.66 gal) Decalcification Compatible with approximately 20% citric acid solution; automated decalcification program required Rinse Interval Automated rinse cycle: minimum every 4 hours; rinse volume 10 L (3 gal) or 10-minute rinse time AutoSTART / AutoSTOP System shall support automatic start in SUPPLY mode via communication cable connection to dialysis machine Disinfection Validation System must provide auditable disinfec

Who won similar work

48 award notices on SAM.gov in the last 24 months. Matched by: Same office (242-NETWORK CONTRACT OFFICE 02 (36C242)), same product/service code (PSC) 6515.

Single-winner award sizes (48): middle half $68K to $614K, median $287K; range $15K to $3.2M.

WinnerAwardsValueLast
SDV OFFICE SYSTEMS LLC5$12.3MApr 8, 2026
BEACON POINT ASSOCIATES LLC3$1.8MAug 5, 2026
FOUR POINTS TECHNOLOGY, L.L.C.3$1.5MSep 10, 2025
Trillamed LLC3$1.5MApr 10, 2026
GEO-MED, LLC2$975KAug 25, 2026
HILL-ROM, INC.2$566KOct 1, 2026
SCRIPTPRO USA INC2$234KMar 13, 2026
Sierra7, Inc.1$1.3MAug 14, 2026
STANDARD COMMUNICATIONS INC1$1.2MAug 18, 2026
AFTER ACTION MEDICAL AND DENTAL SUPPLY, LLC1$725KAug 12, 2026

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in. Revenue next to a ticker is the company's last annual revenue from its 10-K.

Latest awards

Materiality: one award's value as a share of the winner's revenue over the latest 12 months in its SEC filings (or its last fiscal year, as noted when you point at it). Low under 1%, Medium 1 to 5%, High 5% or more. Many awards are paid over several years, so this overstates a single year's share.

Competitive landscape

For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 0 of these past winners lobbied Veterans Affairs, Dept of (VA) since 2024 (0 filings)
  • 0 of their lobbyists list a past Veterans Affairs, Dept of (VA) job
  • No corporate PAC money from them to the overseeing committees since 2024
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 0 bills named on the past winners' lobbying filings
  • 25 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.

  • 0 of the past winners are listed companies
  • 0 insider buys and 0 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.