Z1DA--Repair Fire Doors - Construction Project #565-25-101
Veterans Affairs · 246-NETWORK CONTRACTING OFFICE 6 (36C246)
Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.
Where this opportunity stands
Every notice posted under solicitation 36C24625Q0801 in this department, oldest first.
Next steps for this stage
Standard steps for the notice type; not advice about this buyer.
- Decide bid or no bid before the response deadline.
- Look at the past winners for likely competitors and teaming partners.
- Follow the opportunity to hear about amendments and the award.
What the notice says
?.## STATEMENT OF WORK Repair Fire Doors Project: 565-25-101 Construction Services VAMC Fayetteville, NC SCOPE OF WORK: This project will repair fire and smoke doors located in Building nos. 1 and 3 at the VA Medical Center located at 2300 Ramsey Street, Fayetteville, NC 28301. The work will require door specialists, electricians, wall finishers, and laborers. It is highly recommended that all offerors attend the scheduled site visit walk through to note wall types, existing conditions, required hardware, take rough measurements, etc., necessary for proper offers. Construction will be done in … (show all)
accordance with VA specifications, Design guides, Infection Control guidelines and all applicable codes. VA Standards shall be retrieved from the Office of Construction and Facilities Management website (https://www.cfm.va.gov/til/index.asp). Construction will also be structured to require minimum interruption of space function during construction. The door numbers and work to be completed are as follows: Building no. 1 Basement Floor Room B39 (Soiled Linen) Two-hour fire rating. Provide frame label/re-certify. Room B85 (Linen Chute) Two-hour fire rating. Provide frame label/re-certify. Second Floor Room 2055 (Anesthesia) One-hour fire rating. Provide door label/re-certify. Note that it is a new door and frame so the door label was likely covered by the continuous hinge. Third Floor Room 379 (Stairwell) - Two-hour fire rating. Provide frame label/re-certify. Add door sweep. Fourth Floor Room 419 (Soiled Utility) - One-hour fire rating. Provide frame and door labels/re-certify. Note that it is a new door and frame so the labels were likely covered by the continuous hinge. Building no. 3 Basement Floor Room B05 (Exterior) Two-hour fire rating. Demolition (see note below). Replace metal doors and frame for correct egress (outward). Install new closers, panic bars, lockset, vision lites (large in each door and above doors). Reconnect to maglock and card readers. The existing maglock is operational and works on a schedule. Replace all hardware. Replace ADO push plate on the exterior. On the interior side, replace ADO push plate with wave to open sensor. Provide new controllers. Reinstall air curtain. Install panic bars with egress out. Eliminate electric strike function. Storage function leverset. Install new threshold, weatherstripping, and sweeps. Room B07 (Storage) Two-hour fire rating. Demolition (see note below). Replace wood doors and metal frame for correct egress (outward). Install new closers, panic bars, lockset/keypad. Room B10 (Electrical) - Two-hour fire rating. Demolition (see note below). Replace metal door and frame. Install new closer and lockset. Room 06L (Office) - Two-hour fire rating. Provide door and frame labels/re-certify. Room B06P (Corridor) - Two-hour fire rating. Demolition (see note below). Replace metal doors and frame. Install lockset, panic bars, closers. Install wave to open sensors instead of ADO push buttons. Must maintain same level of security and automation. First Floor Room 105 (Storage) - Two-hour fire rating. Demolition (see note below). Replace metal door and frame. Install new closer, lockset and cylindrical deadbolt. Reinstall maglock and card reader. Room 109 (Storage) - Two-hour fire rating. Provide frame label/re-certify. Second Floor Room 203B3 (Storage) - Two-hour fire rating. Replace wood door. Reinstall frame mounted door stop, add new closer and lockset. Dispose of door. Located between Building nos. 1 and 3 Basement Floor Door BX (exterior door to courtyard ramp) - Replace metal door and hardware located between buildings nos. 1 and 3. Install new metal door, rated sight glass, sweep, kick plates, maglock, card reader, door and wave to open sensor on the interior and ADO push plate on exterior. Notes: Demolition entails removal and disposal. Includes destructive actions of parts of block, plaster and/or gypsum walls. Walls to be refinished to match existing walls. Infection control measures must be taken as directed by VA (assume plastic barriers, air scrubber, sticky mat, and covered carts). For the frame and door labels, they shall be metal (i.e., not a sticker). Panic bars shall be UL-Listed fire exit devices. Contractor to plan on doing one door at a time. The VA may consider allowing more than one door worked on at a time. For it to be considered, the contractor must have a well-developed plan and adequate personnel to complete the work as quickly as possible. Life safety (stairwell door, path of egress) will be scrutinized. There is considerable distance between each door location. SCHEDULE: Contractor to complete construction within 150 calendar days of the Notice to Proceed. This should allow sufficient time for submittals and material lead times, as well as actual construction. WORKING HOURS: Frame labeling/re-certifying can happen during normal working hours (e.g., 0730-1700). Demolition and construction work shall be performed after normal working hours (e.g,. 1700-0700). COR may allow some exceptions if VA Safety and Infection Control offices allow (e.g., painting, finishing). SCHEDULED SITE VISIT: This SOW doesn t contain all the necessary information for contractors to prepare proper offers. Therefore, the schedule site visit walk-through is highly recommended. There interested offerors are to record the wall types; take rough measurements; note existing door operators, hardware, etc.; observe surroundings and visualize necessary infection control measures. A VA Locksmith will be part of the site visit to assist in answering questions onsite. BADGING: The VA will provide contractors temporary badging. All badges shall be returned to the VA. MEETINGS: Bi-weekly progress meetings will follow the Notice to Proceed. Weekly meetings will commence once a materials delivery date is established. ATTACHMENTS: See attached document: Repair Fire Doors Project 565-25-101 Specifications. See attached document: Repair Fire Doors Project 565-25 101 Photos of Doors. (End Statement of Work)
Who won similar work
3 award notices on SAM.gov in the last 24 months. Matched by: Same office (246-NETWORK CONTRACTING OFFICE 6 (36C246)), same product/service code (PSC) Z1DA and NAICS 236220.
Single-winner award sizes (3): middle half $595K to $2.4M, median $992K; range $197K to $3.8M.
| Winner | Awards | Value | Last |
|---|---|---|---|
| PHILLIPS C&C LLC | 2 | $4.8M | May 20, 2026 |
| REVELS CONTRACTING SERVICES, INC | 1 | $197K | Sep 19, 2025 |
Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in. Revenue next to a ticker is the company's last annual revenue from its 10-K.
- May 20, 2026PHILLIPS C&C LLC$3.8MZ1DA--Renovate Main LobbyNo listed company matched (Materiality N/A)
- Feb 20, 2026PHILLIPS C&C LLC$992KZ1DA--658-24-106 Replace Bldg 16 HVACNo listed company matched (Materiality N/A)
- Sep 19, 2025REVELS CONTRACTING SERVICES, INC$197KZ1DA--Replace X-Ray Room 4No listed company matched (Materiality N/A)
Competitive landscape
For the 2 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
- 0 of these past winners lobbied Veterans Affairs, Dept of (VA) since 2024 (0 filings)
- 0 of their lobbyists list a past Veterans Affairs, Dept of (VA) job
- No corporate PAC money from them to the overseeing committees since 2024
- 0 foreign-agent (FARA) registrations
Policy around it
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
- 0 bills named on the past winners' lobbying filings
- 25 rules from the department in the last 12 months
- 0 executive orders naming the agency in the last 12 months
Market
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.
- 0 of the past winners are listed companies
- 0 insider buys and 0 insider sells at them in the last 90 days
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.