Equipment: 7T MRI System with a dedicated, high-performance, local gradient subsystem.
National Institutes of Health · NATIONAL INSTITUTES OF HEALTH NICHD
Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.
Where this opportunity stands
Every notice posted under solicitation RFP-2026-NIH-7TMR in this department, oldest first.
Next steps for this stage
Standard steps for the notice type; not advice about this buyer.
- Decide bid or no bid before the response deadline.
- Look at the past winners for likely competitors and teaming partners.
- Follow the opportunity to hear about amendments and the award.
What the notice says
This solicitation is amended to add Amendment 0004 SF-30 This solicitation is amended to add Amendment 0003 SF-30 and Continuation Pages/Sheets and Wage Determination Attachment. There are no other changes to this solicitation. This solicitation is amended to add the following attachment: Amendment 0002 This solicitation is amended to add the following attachments: 1.Amendment 00001 Questions and Answers Log 2. Amendment 0001 Description of Modifications - Block 14 COMBINED SYNOPSIS / SOLICITATION SOLICITATION NUMBER: RFP-2026-NIH-7TMR AGENCY: National Institutes of Health (NIH) NAICS CODE: 33… (show all)
4510 . Electromedical and Electrotherapeutic Apparatus Manufacturing CONTRACT TYPE: Firm-Fixed-Price (FFP), Single-Award PROCEDURE: Negotiated RFP - Combined FAR Part 12 and FAR Part 15 RELEASE DATE: September 5, 2026 QUESTIONS SUBMISSION DEADLINE: September 9, 2026, by 5pm EDT. RFP RESPONSE DEADLINE: September 18, 2026, by 5pm EDT POINT OF CONTACT: Tina Robinson @ robinsti@mail.nih.gov 1. Description of Requirement & Scope of Work This is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in FAR Subpart 12.6, as streamlined by the active Federal Acquisition Regulation (FAR) commercial streamlining guidelines, and supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The specific objective of this purchase is the acquisition of a 7T MRI System with a dedicated, high-performance, local gradient subsystem. The acquisition will allow the FMRIF to be able to provide the latest tools and techniques to NIH researchers to collect high quality brain imaging data from patients and research volunteers and develop novel scanning protocols advancing the state-of-the-art for structural and functional brain imaging. The upgraded system is to be used for clinical and preclinical human MRI research. The National Institutes of Health (NIH), National Institute of Mental Health (NIMH), Functional Magnetic Resonance Imaging Core (FMRIF) Center requires the acquisition of a new, research-dedicated 7-Tesla (7T) Ultra-High Field Magnetic Resonance Imaging (MRI) System or Technical Equal, a complete turn-key physical installation within the FMRIF Center, and the trade-in extraction and removal of an existing legacy Siemens 7T Plus MRI system. The Contractor shall provide all equipment, personnel, engineering project management, specialized rigging, mechanical installation, calibration, onsite applications training, and legacy de-installation/trade-in services necessary to deliver and make fully operational the ultra-high field system under a single-award, Firm-Fixed-Price contract structure. 2. Section B: Supplies or Services and Prices/Costs Bids must reflect the best and final price for a complete, turn-key delivery. Pursuant to standard commercial unbundling rules, pricing is separated into independent supply, service, and option Contract Line Item Numbers (CLINs) to ensure strict accountability and invoice integrity. B.1 Contract Line Item Number (CLIN) Structure - SEE ATTACHMENT B.2 Total Evaluated Price Calculation Formula - SEE ATTACHMENT Section C: Statement of Work & Technical Salient Characteristics Alternative systems must strictly comply with the following mandatory engineering baselines to be deemed technically acceptable: 1. Magnet Core Assembly . Field Strength: Superconducting, actively shielded 7.0 Tesla (7.0T) magnet body suitable for human patient studies. . Field Homogeneity: Less than 5 ppm peak-to-peak over a 25 cm Diameter Spherical Volume (DSV) fully shimmed with superconducting and/or passive shims. . Spectral Linewidth: Water spectral linewidth of less than 0.1 ppm Full Width Half Height (FWHH) over a 25 cm DSV. . Field Drift Rate: Main field drift less than 0.05 ppm/hour without field drift compensation, and less than 0.005 ppm/hour with field drift compensation actively enabled. . Cryogenic System: Zero boil-off technology for continuous liquid helium preservation. . Emergency Infrastructure: Integrated physical safety switch to shut off the main magnetic field quickly and safely during an emergency (final location designated at installation). . Ramp Profile: Vendor must specify exact magnet ramp-up and ramp-down times following installation or service. Faster ramp times are preferred. 2. Room Temperature Shim & Gradient Coils . Physical Clearance: Local head gradient system featuring an internal clear bore diameter of at least 40 cm free, available space. . Gradient Performance: Amplifiers capable of generating a maximum peak amplitude of at least 200 mT/m along each axis simultaneously with a maximum slew rate of at least 900 T/m/s with the supplied coil. . Active Shimming: Room temperature active shim coil set consisting of at least 8 independent channels (3 first-order and 5 second-order terms) with a dedicated power supply, fully controlled via the central operator console software environment. . Waveform Architecture: Control unit operating with at least 10 ��s time resolution and 16-bit amplitude resolution. . Field Stability: Better than 0.5% deviation at maximum gradient strength on each axis. . Thermal Protection: Dedicated hardware and software mechanisms to dynamically protect gradients and amplifiers from thermal overheating. 3. Radio Frequency (RF) Electronics & Coils . Parallel Transmit Array: Transmitter system featuring 8 independently controllable RF transmit channels operating at frequencies suitable for protons (1H). . Amplifier Output: RF transmit amplifiers supplying at least 1 kW pulsed, linear, on-resonance power independently per channel. All RF channels driven by independent waveform generators with adequate waveform memory supporting concurrent amplitude and phase modulation. . SAR Safety Subsystem: Real-time RF transmit power monitoring on all individual channels with an automatic control mechanism ensuring estimated local and average Specific Absorption Rate (SAR) metrics remain below FDA/IEC guidelines. Includes power-limiting safety boundaries for individual transmit elements. . Digital Receivers: A minimum of 64 digital receiver channels capable of receiving on-resonance MRI signals in parallel. . Multinuclear Broadening: At least 8 receiver channels must be broadband (10.298 MHz), configured to detect non-proton nuclei including 1H, 1.F, 31P, 13C, and 23Na. . Receiver Metrics: Minimum digital sampling bandwidth of at least 1 MHz with at least 16-bit dynamic range, allowing direct user access within the full range of imaging sequences to raw, pre-reconstruction MR sampled data. . Included RF Array: Delivered with a minimum of one high-performance human head RF coil, configured as a multi-channel transmit and 64-channel receive array (8Tx/64Rx) optimized for accelerated imaging (GRAPPA, SENSE, and Simultaneous Multislice/Multiband). . Open-Source Coils: Full specifications and interface tools to enable the secure attachment and operation of customer-developed, custom-built RF coils. . External Gating: Subsystem for gated data acquisition with a minimum of 2 independent external signals and 4 BNC TTL output lines, providing digital recording and real-time display of respiratory and cardiac waveforms. 4. Host Operator Console & Image Reconstruction Computer . Host System: State-of-the-art host workstation with current scanner operation, protocol planning, and image viewing software supporting automated shimming optimization for individual human subjects. Software must support acquisition and processing of advanced neuro-MRI and spectroscopy applications. . Reconstruction Hardware: Dedicated high-end image reconstruction computer supporting advanced neuro-MRI and spectroscopy algorithms. . Real-Time Processing: Capable of acquiring and reconstructing 64-channel data in real-time during accelerated (R4) gradient-echo echo
Who won similar work
25 award notices on SAM.gov in the last 24 months. Match: Same agency (National Institutes of Health), same industry group (NAICS 3345).
| Winner | Awards | Value | Last |
|---|---|---|---|
| AGILENT TECHNOLOGIES INC · $A | 2 | $401K | Jul 24, 2025 |
| GOVERNMENT SCIENTIFIC SOURCE INC | 2 | $283K | Dec 17, 2025 |
| 10X GENOMICS, INC. · $TXG | 2 | $77K | Sep 22, 2025 |
| GE PRECISION HEALTHCARE LLC | 1 | $5.9M | Sep 17, 2025 |
| FEI COMPANY | 1 | $1.8M | Sep 22, 2025 |
| BRUKER BIOSPIN CORP · $BRKR | 1 | $1.4M | Sep 18, 2025 |
| BECTON, DICKINSON AND COMPANY · $BDX | 1 | $1.3M | Jan 3, 2025 |
| BRUKER NANO, INC · $BRKR | 1 | $230K | Aug 14, 2026 |
| Sony Biotechnology Inc. | 1 | $227K | Aug 17, 2026 |
| NEWPORT CORP | 1 | $212K | Jul 8, 2026 |
Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.
- Oct 9, 2026Revvity Health Sciences, Inc.$21KAutomated Cell Counter and Analyzer
- Sep 25, 2026NIKON INSTRUMENTS INC$40K66--Warming Box/Enclosure for Nikon Eclipse Ti-2 AX co
- Aug 17, 2026Sony Biotechnology Inc.$227K66--NIMH: Purchase order for One (1) Microfluidic Base
- Aug 14, 2026BRUKER NANO, INC$230K66--NIMH: Purchase order for One (1) Miniaturized Head
- Aug 7, 2026BITTIUM USA INC.$48K66--NIMH: Non Competitive Combined Synopsis for Faros
- Jul 10, 2026BECKMAN COULTER, INC$31K66--Purchase Order for two (2) Hematology Analysers
- Jul 10, 2026AMUZA INC.$115K66--NIMH: Purchase order for four (4) wireless fiber p
- Jul 8, 2026NEWPORT CORP$212K66--RFQ for One (1) Tunable Laser Multi-Photon Microsc
- Jul 8, 2026SR RESEARCH LIMITED$37K66--NIMH: Purchase Order for One (1) EyeLink 1000 Plus
- Jul 8, 2026PARSE BIOSCIENCES, INC.$67K66--PO for One (1) Evercode WT v3 with UDI Plate and
Competitive landscape
For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
- 0 of these past winners lobbied Natl Institutes of Health (NIH) since 2024 (0 filings)
- 0 of their lobbyists list a past Natl Institutes of Health (NIH) job
- $45K from their corporate PACs since 2024 to members of House Committee on Appropriations, House Committee on Energy and Commerce, Senate Committee on Appropriations, Senate Committee on Health, Education, Labor, and Pensions
- 0 foreign-agent (FARA) registrations
Policy around it
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
- 0 bills named on the past winners' lobbying filings
- 0 rules from the department in the last 12 months
- 0 executive orders naming the agency in the last 12 months
Market
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.
- 4 of the past winners are listed companies
- 0 insider buys and 8 insider sells at them in the last 90 days
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.