Spectroradiometer with specialized lens for characterizing head mounted displays
FDA · FDA OFFICE OF ACQ GRANT SVCS
Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.
Where this opportunity stands
Every notice posted under solicitation FDA_RFQ_CDRH_2026_133605 in this department, oldest first.
- Sep 8, 2026Combined Synopsis/SolicitationOpen
- Sep 8, 2026 · this noticeCombined Synopsis/Solicitation
Next steps for this stage
Standard steps for the notice type; not advice about this buyer.
- Decide bid or no bid before the response deadline.
- Look at the past winners for likely competitors and teaming partners.
- Follow the opportunity to hear about amendments and the award.
What the notice says
Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. Background: The procurement is to support regulatory science tools development for the Interventional, Radiological Imaging and Visualization program. Developing measurement methodologies for technical performance is critical for consistent evaluation of image visualization on head mounted displ… (show all)
ays. Specifically, the procurement is for a spectroradiometer to precisely measure and evaluate the spectrum and color performance of image quality of augmented and virtual reality head mounted displays that are increasingly being incorporated in medical devices across the Office of Product Evaluation and Quality (OPEQ). The quantitative measurements from the spectroradiometer will allow for developing image quality regulatory science tools for a wider range image quality parameters across the full range of device types, opposed to only measuring luminance values. The specialized lens assembly on the spectroradiometer mimics the human visual system, which is critical for determining the image quality seen by the user. This will align the Office of Science and Engineering Laboratories (OSEL) instrumentation with FDA recognized standards, such as the International Electrotechnical Commission (IEC), for head mounted displays, which is essential for the OSEL mission of developing regulatory science tools. Minimum Performance Requirements: Item 1: Spectroradiometer Optical Specifications: � Wavelength range: at least 380-780 nm � Sensor size: at least 512 elements � Detector type for spectroradiometer: back-thinned and cooled CCD � Spectral resolution/Spectral bandwidth: < 5 nm, option for variable resolution preferable � Datapoint interval/Spectral reporting: 1 nm or less � Digital resolution: 16 bits Performance Specifications: � Wavelength accuracy: < 0.5 nm � Luminance accuracy: < +/- 3% � Integration time range: minimum 10 ms to 60 seconds � Stray light: less than 0.06% � Polarization error: less than 2% � Sensitivity: at least 5*10^-5 cd/m2 with a 2 degrees internal aperture measuring Illuminant A � Color accuracy (x,y): less than +/- 0.002 � Color repeatability (x,y): less than +/- 0.0005 Hardware Features � Variable internal aperture diameters: 2 degrees, 1 degree, and 0.1-0.25 degrees � Integrated neutral density filter: ND1 or ND2 � Communication: USB � Physical dimension: less than 20 cm x 36 cm x 36 cm � Weight: < 10 kg Item 2: Specialized lens for measuring near eye displays, including augmented and virtual reality displays The contractor shall provide a specialized lens optimized for measuring augmented reality (AR) and virtual reality (VR) displays with the following specifications: � Focal length: 30-50 mm � Front entrance pupil design with a fixed pupil with a diameter between 3 mm and 5 mm � Adjustable focus range: at least 300 mm to infinity � Luminance accuracy: < +/- 3% Item 3: Software The contractor shall provide software with the following capabilities: Core Functions: � Control spectroradiometer operations � Acquire measurements � Display spectrum and color measurements � Analyze measurement data Data Export: � Export raw data in Excel, ASCII, or equivalent formats Integration: � Software Development Kits (SDKs) or command line support for third-party software control � Compatible with Python and MATLAB � Compatible with Windows 10 Operating System or later versions � Compatible with Windows 10, Windows 11, or Linux Operating System Deliverables: The Contractor shall deliver the item and quantities ordered within 60 days of award. The Contractor shall deliver the following items and quantities ordered, all, or none: � Spectroradiometer system (Item 1) - fully calibrated and tested � Specialized lens for near-eye displays (Item 2) � Control and analysis software (Item 3) with installation media and documentation � Calibration certificate(s) or test report(s) � User manuals and technical documentation for all equipment � Software documentation including SDK/API documentation Place of Supply Delivery and Place of Performance: The equipment should be complete with all accessories and software necessary to work and to be delivered to: Attention: Yasaman Ardeshirpour U.S. Food and Drug Administration White Oak Building 62 Room 1112 10903 New Hampshire Ave, Silver Spring, MD 20993-0002 Period of Performance: 12-month Base Year and Four, 12-month Option Years commencing upon date of award. Please see the attached Statement of Work and corresponding ancillary documents for review and consideration. Quotes are due by email on or before September 14, 2026, by 4:00 P.M. (Eastern Standard Time) and should be sent to brandon.rafus@fda.hhs.gov.
Who won similar work
24 award notices on SAM.gov in the last 24 months. Match: Same agency (FDA), any industry: a loose match.
Loose match: same agency, any industry. Read the titles before treating these as competitors.
| Winner | Awards | Value | Last |
|---|---|---|---|
| Please_See_Spreadsheet Silver Spring MD 20993 USA | 3 | $153.2M | Oct 8, 2026 |
| DCT, INCORPORATED | 1 | $52.8M | Sep 15, 2026 |
| TRANQUIL CLINICAL AND RESEARCH CONSULTING SERVICES LLC | 1 | $50.0M | Sep 16, 2025 |
| NATI-NVE Support Services, LLC | 1 | $49.0M | May 21, 2026 |
| HARVARD PILGRIM HEALTH CARE INC | 1 | $31.7M | Mar 30, 2026 |
| TOXICOLOGIC PATHOLOGY ASSOCIATES INC | 1 | $26.1M | Sep 15, 2025 |
| IHRC, INCORPORATED | 1 | $14.5M | Sep 16, 2026 |
| VITALANT Scottsdale AZ 85258 USA | 1 | $10.0M | Sep 8, 2025 |
| WE PHARMA, INC. | 1 | $4.0M | Sep 11, 2026 |
| THE BIONETICS CORP | 1 | $2.8M | Jul 21, 2025 |
Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.
- Oct 8, 2026Please_See_Spreadsheet Silver Spring MD 20993 USA$120.8MFY26 FDA Broad Agency Announcement (BAA) for Advanced Research and Development of Regulatory Science
- Sep 24, 2026TRADESPACE INC$82KPlatform Subscription to Support Transfer Program Commercial Assessment Leads
- Sep 24, 2026TURBOFIL PACKAGING MACHINES, LLC$454KAutomated Vial Capper Machine and Labeler system
- Sep 22, 2026ABIDE INTERNATIONAL, INC.$1.8MBuilding Exterior Repair Project � FDA Pacific Southwest Laboratory
- Sep 17, 2026LUSARDI CONSTRUCTION CO. San Marcos CA 92078 USA$779KIRV Exhaust and Vacuum Pump Replacement
- Sep 16, 2026IHRC, INCORPORATED$14.5MFDA Occupational Safety, Industrial Hygiene, Information Systems, and Training (OSIST) IDIQ
- Sep 15, 2026DCT, INCORPORATED$52.8MNational Center for Toxicological Research (NCTR) on-site facility Operations and Maintenance (O&M) support services
- Sep 11, 2026WE PHARMA, INC.$4.0MPharmaceutical Products for CDER Research Studies - IDIQ
- Aug 31, 2026GOVERNMENT SCIENTIFIC SOURCE INC$399KDigital Slide Scanner System
- Aug 21, 2026Z-SPEC, INC.$123KPost-Award Public Notice
Competitive landscape
For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
- 0 of these past winners lobbied Food & Drug Administration (FDA) since 2024 (0 filings)
- 0 of their lobbyists list a past Food & Drug Administration (FDA) job
- No corporate PAC money from them to the overseeing committees since 2024
- 0 foreign-agent (FARA) registrations
Policy around it
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
- 0 bills named on the past winners' lobbying filings
- 129 rules from the department in the last 12 months
- 0 executive orders naming the agency in the last 12 months
Market
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.
- 0 of the past winners are listed companies
- 0 insider buys and 0 insider sells at them in the last 90 days
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.