EVOS M5000 microscope for monitoring and documenting cultured cell images
National Institutes of Health · NATIONAL INSTITUTES OF HEALTH OLAO
Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.
Where this opportunity stands
Every notice posted under solicitation 75N98026Q01227 in this department, oldest first.
- Sep 16, 2026 · this noticeCombined Synopsis/Solicitation
Next steps for this stage
Standard steps for the notice type; not advice about this buyer.
- Decide bid or no bid before the response deadline.
- Look at the past winners for likely competitors and teaming partners.
- Follow the opportunity to hear about amendments and the award.
What the notice says
1.0 DESCRIPTION This is a combined synopsis/solicitation for commercial products prepared in accordance with RFO FAR Part 12. This announcement constitutes the only solicitation. Quotations are being requested, and a separate written solicitation will not be issued. Solicitation No. 75N98026Q01227 is issued as a Request for Quotation (RFQ) for EVOS M5000 Microscope for Monitoring and Documenting Cultured Cell Images. The Department of Health and Human Services (HHS), National Institutes of Health (NIH), National Institute of Environmental Health Sciences (NIEHS), intends to procure, on a sole … (show all)
source basis, an EVOS M5000 Imaging System from the manufacturer, Thermo Fisher Scientific. The EVOS M5000 Imaging System is required to support cell imaging and analysis conducted by the laboratory within the National Institute of Environmental Health Sciences (NIEHS). The system will be used to image and analyze cells grown in culture and is a critical component of new and ongoing research projects. The EVOS M5000 Imaging System will replace aging and outdated imaging equipment that no longer meets the laboratory's current requirements for work involving cultured cells. The required system provides the specific combination of capabilities necessary for the laboratory's research, including a compact, fully integrated configuration suitable for use within the laboratory's existing biological safety cabinet (BSC); position tracking for longitudinal monitoring of live cells; integrated quantitative analysis for cell counting, confluence, and transfection/transduction efficiency; and multi-modal imaging of both live cultured cells and fixed or fluorescently stained specimens. The Government intends to procure the EVOS M5000 Imaging System on a sole-source basis from Thermo Fisher Scientific. The required system includes a fully integrated digital inverted microscope capable of four-color fluorescence, transmitted-light, and color imaging; a high-sensitivity 3.2 MP monochrome camera; autofocus; Z-stacking; time-lapse imaging; position-sensing X/Y stage and software-based location tracking; and onboard software for cell imaging and quantitative analysis. The system is required to support cell counting, confluence assessment, and determination of transfection/transduction efficiency and shall be capable of imaging live cells and fixed or fluorescently stained cells in culture vessels and on glass microscope slides. The system shall be sufficiently compact and fully integrated to operate within the laboratory's existing biological safety cabinet. The laboratory conducted market research and evaluated commercially available alternatives to avoid unnecessarily restricting this acquisition to a single manufacturer. Three systems were evaluated, including the Thermo Fisher Scientific EVOS M5000 Imaging System, the ECHO Revolve, and the Logos Biosystems CELENA S Digital Imaging System. Manufacturer specifications and system capabilities were reviewed and compared, including physical configuration and footprint, live-cell imaging capabilities, fluorescence and transmitted-light imaging, sample compatibility, cell-analysis functions, and longitudinal imaging capabilities. Although the ECHO Revolve and CELENA S provide several comparable microscopy functions, neither was identified as providing the complete combination of capabilities required by the laboratory. The EVOS M5000 was therefore determined to meet the laboratory's overall technical and operational requirements. Due to the specialized nature of the laboratory's research and the Government's requirement for the specific combination of a fully integrated microscope configuration, BSC compatibility, live-cell imaging, position tracking, quantitative cell-analysis capabilities, and multi-modal imaging, the Government intends to procure the EVOS M5000 Imaging System on a sole-source basis from Thermo Fisher Scientific. Thermo Fisher Scientific manufactures the EVOS M5000 Imaging System and, based on the market research conducted, is the only source identified that can satisfy the Government's complete combination of scientific and technical requirements. Use of an alternate system could require modifications to the laboratory's established imaging workflow and methodologies and could affect the laboratory's ability to conduct longitudinal cell monitoring and consistent quantitative analysis. The contractor shall provide the Thermo Fisher Scientific EVOS M5000 Imaging System in accordance with the requirements of this solicitation. The system shall provide a fully integrated digital inverted microscope capable of four-color fluorescence, transmitted-light, and color imaging; a high-sensitivity 3.2 MP monochrome camera; autofocus; Z-stacking; time-lapse imaging; position-sensing X/Y stage and software-based location tracking; and onboard software for cell imaging and quantitative analysis. The system shall support cell counting, confluence assessment, and determination of transfection/transduction efficiency and shall be capable of imaging live cells and fixed or fluorescently stained cells in culture vessels and on glass microscope slides. The system shall be sufficiently compact and fully integrated to operate within the laboratory's existing biological safety cabinet. The contractor shall deliver the required equipment to NIEHS in Rall Building 101, laboratories E144-146, located at 111 T.W. Alexander Drive, Research Triangle Park, North Carolina 27709. Acceptance will be demonstrated by successful delivery and successful operation of the specified imaging system within the NIEHS laboratory. There is no travel for this purchase. This RFQ is being posted to the Governmentwide Point of Entry (GPE) in accordance with RFO FAR 5.201. This acquisition will be conducted in accordance with RFO FAR Part 12 � Acquisition of Commercial Products and Commercial Services, using the simplified procedures at RFO FAR 12.201-1. Required delivery date: September 25, 2026 Delivery Location: NIEHS, Rall Building 101, Laboratories E144-146, 111 T.W. Alexander Drive, Research Triangle Park, NC 27709 The applicable NAICS code is 334516 � Analytical Laboratory Instrument Manufacturing. The applicable PSC is 6650 � Optical Instruments, Test Equipment, Components and Accessories. Please see the attached requirements document titled �75N98026Q01227 � Requirements Document� for additional information. 2.0 UNIQUE QUALIFICATIONS OF THE CONTRACTOR The proposed contractor, Thermo Fisher Scientific, is the manufacturer of the required EVOS M5000 Imaging System for cell imaging and analysis conducted by the laboratory within the National Institute of Environmental Health Sciences (NIEHS). The required equipment is a specialized, fully integrated digital inverted microscope designed to provide four-color fluorescence, transmitted-light, and color imaging of cultured cells and fixed or fluorescently stained specimens. The system includes a high-sensitivity 3.2 MP monochrome camera, autofocus, Z-stacking, time-lapse imaging, position tracking, and integrated software for quantitative cell analysis, including cell counting, confluence assessment, and determination of transfection/transduction efficiency. The EVOS M5000 Imaging System is specialized research equipment required to support the Government's established approach for imaging and analyzing cells grown in culture, including live-cell longitudinal monitoring and analysis of fixed or fluorescently stained specimens. The system's compact, fully integrated configuration is required to permit operation within the laboratory's existing biological safety cabinet while providing the imaging, position-tracking, and quantitative analysis capabilities necessary for the laboratory's research. Due to the specific combination of required physical configuration, BSC compatibility, live-cell imaging, position tracking, quantitative cell-analysis capabilities, and multi-modal imaging, use of an alternate system co
Who won similar work
10 award notices on SAM.gov in the last 24 months. Match: Same office, same NAICS 334516.
| Winner | Awards | Value | Last |
|---|---|---|---|
| BRUKER NANO, INC · $BRKR | 1 | $230K | Aug 14, 2026 |
| Sony Biotechnology Inc. | 1 | $227K | Aug 17, 2026 |
| NEWPORT CORP | 1 | $212K | Jul 8, 2026 |
| AMUZA INC. | 1 | $115K | Jul 10, 2026 |
| PARSE BIOSCIENCES, INC. | 1 | $67K | Jul 8, 2026 |
| Mirion Technologies (Capintec), Inc. | 1 | $56K | Jun 29, 2026 |
| NIKON INSTRUMENTS INC | 1 | $40K | Sep 25, 2026 |
| SR RESEARCH LIMITED | 1 | $37K | Jul 8, 2026 |
| BECKMAN COULTER, INC | 1 | $31K | Jul 10, 2026 |
| Revvity Health Sciences, Inc. | 1 | $21K | Oct 9, 2026 |
Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.
- Oct 9, 2026Revvity Health Sciences, Inc.$21KAutomated Cell Counter and Analyzer
- Sep 25, 2026NIKON INSTRUMENTS INC$40K66--Warming Box/Enclosure for Nikon Eclipse Ti-2 AX co
- Aug 17, 2026Sony Biotechnology Inc.$227K66--NIMH: Purchase order for One (1) Microfluidic Base
- Aug 14, 2026BRUKER NANO, INC$230K66--NIMH: Purchase order for One (1) Miniaturized Head
- Jul 10, 2026AMUZA INC.$115K66--NIMH: Purchase order for four (4) wireless fiber p
- Jul 10, 2026BECKMAN COULTER, INC$31K66--Purchase Order for two (2) Hematology Analysers
- Jul 8, 2026SR RESEARCH LIMITED$37K66--NIMH: Purchase Order for One (1) EyeLink 1000 Plus
- Jul 8, 2026NEWPORT CORP$212K66--RFQ for One (1) Tunable Laser Multi-Photon Microsc
- Jul 8, 2026PARSE BIOSCIENCES, INC.$67K66--PO for One (1) Evercode WT v3 with UDI Plate and
- Jun 29, 2026Mirion Technologies (Capintec), Inc.$56K66--PO Three(3) Capintec CRC-55tr Dose Calibrator Syst
Competitive landscape
For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
- 0 of these past winners lobbied Natl Institutes of Health (NIH) since 2024 (0 filings)
- 0 of their lobbyists list a past Natl Institutes of Health (NIH) job
- No corporate PAC money from them to the overseeing committees since 2024
- 0 foreign-agent (FARA) registrations
Policy around it
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
- 0 bills named on the past winners' lobbying filings
- 0 rules from the department in the last 12 months
- 0 executive orders naming the agency in the last 12 months
Market
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.
- 1 of the past winners are listed companies
- 0 insider buys and 0 insider sells at them in the last 90 days
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.