Loading the records…
Loading the records…
Coast Guard · CG-SEA-C22
Coast Guard wants bids for "USCGC Polar Star 1000KW Generator Rental". The work is in JBPHH, HI, USA. The original due date (Nov 23, 2026) has passed; check the latest amendment for the current one. In the last 2 years, similar work went to 3 companies, usually for about $1.7M per award. An award is expected between December 2026 and January 2027.
Put together from the facts on this page; the details and sources are below.
Your briefs and their views: My briefs.
Every notice posted under solicitation 70ZU0227Q0001264 in this department, oldest first.
Standard steps for the notice type; not advice about this buyer.
generator package meeting the requirements below to the delivery location identified in this SOW for an anticipated rental period of approximately six months. The contractor shall also retrieve the generator package from the pier at the end of the rental period. Minimum power rating 750 kW (prime), maximum 1000 kW, 450/480 VAC, 3-phase, 3-wire power. Generator must be able to withstand 1.5 times rated current for up to 30 seconds. Minimum generator insulation class F. Electrically operated generator circuit breaker, of either insulated-case or power circuit breaker type, must be installed for protection of the generator and the connecting power cable, with electronic trip unit capable of long-, short-, and instantaneous tripping. Circuit breaker must be rated for minimum 45 kA asymmetric interrupt rating. Protection settings must be set for generator protection in accordance with American Bureau of Shipping (ABS) Marine Vessel Rules (MVR) 2025 Part 4, Chapter 8, Section 2, Paragraph 9.11 (4-8-2/9.11). Specifically: Overload protection Short-circuit protection Thermal damage protection Reverse power protection Prime mover shutdown Undervoltage protection 300� of cable rated for 115% of generator maximum current in 40 deg C ambient, minimum 90 deg C rated cable. Cable must be rated for flexible service, single conductors no larger than 4/0 for purposes of installation on the ship. Generator must be enclosed in a standard 30-foot or 40-foot shipping container. Exact specifications and dimensions must be provided in the proposal. Internal lighting, and all necessary control systems for operators to manage the system inside the container must be installed. Generator engine must be electrically started. Battery capacity must be sufficient when fully charged for at least 10 starts. Switchgear and bus bar must be braced for asymmetric short-circuit carrying capacity of the generator. The container must include a radiant cooling system capable of maintaining generator temperature in a range of ambient temperatures. The generator must be capable of operation in ambient temperatures of 15 degrees F to 100 degrees F. The generator fuel system must be capable of being refueled while on-line, may be connected to ship�s power for heaters and battery chargers, but must not require any other fluid or system inputs from the ship. The generator and container must be suitable for marine use on board a ship, and the container must have suitable protection from rain, salt spray, low-level flooding from waves, snow, ice, and operating angles up to 15 degrees. It must have physical connections for attachment on deck, and external grounding points for grounding container to the hull. Generator must not have neutral grounding, and any installed ground protection features must be disabled. Grounding of the container will be installed by the Government. Fuel tank must be suitable for generator operation at 50% prime rated power without refueling for 24 hours. Excitation system must not require external power source or field flashing prior to operation. Heaters must be provided to support generator operation within 15 minutes. Exhaust system must include suitably sized spark arrestor and silencer. Generator total harmonic distortion must be less than 3%. Tasks. The contractor shall provide operator and maintenance instructions necessary for the Government to operate and maintain the generator during the rental period. The contractor shall also provide any filter kits and consumables included in the rental package for routine Government-performed maintenance during the rental period, if applicable. The contractor is not responsible for performing routine operation, fueling, hookup, or maintenance during the rental period unless separately stated in the contract. Delivery To/ Place of Performance: USCGC POLAR STAR will be located in Pearl Harbor, HI, Joint Base Pearl Harbor-Hickam, 850 Ticonderoga St, JBPHH. The contractor�s responsibility is limited to delivery of the generator package to the pier adjacent to the cutter and retrieval of the generator package from the pier at the end of the rental period. The Government will provide crane support, place the generator aboard the cutter, perform hookup and grounding, provide fuel, and perform operation and routine maintenance. Period of performance- 10 December 2026 through 30 June 2027. Acceptance. The generator rental will be accepted when the contractor has: delivered the generator package to the specified pier location by the required delivery date; provided a unit that conforms to the electrical and physical characteristics stated in this SOW; provided the required cables, connectors, and operating/maintenance instructions; and delivered the unit in serviceable condition, free of visible shipping damage. Points of Contact. USCG-SFLC-LRE PL Asset Management: CWO Matthew Temple, matthew.temple@uscg.mil, (510) 460-8195 USCG-SFLC-LRE PL Asset Management: LCDR Andrew Constant, Andrew.S.Constant@uscg.mil USCGC POLAR STAR Engineering Officer: Joshua Herring, Joshua.C.Herring@uscg.mil
3 award notices on SAM.gov in the last 24 months. Matched by: Same office (CG-SEA-C22), same NAICS 336611.
Single-winner award sizes (3): middle half $1.3M to $2.1M, median $1.7M; range $838K to $2.6M.
| Winner | Awards | Value | Last |
|---|---|---|---|
| Pacific Shipyards International, LLC | 1 | $2.6M | Nov 5, 2026 |
| GI Industrial-Marine North Charleston SC USA | 1 | $1.7M | Nov 2, 2026 |
| WEPFER MARINE, INC. | 1 | $838K | Oct 27, 2026 |
Value counts new single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling (same contract, or the same office, day and amount); that ceiling is not one company's win, so it is not added in. Contract modifications are not new awards and are not added in either. Notices whose amount is a placeholder such as $999,999,999 are not added in. Revenue next to a ticker is the company's revenue over the latest 12 months in its SEC filings.
For the 3 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
None of these past winners filed lobbying reports naming U.S. Coast Guard (USCG) since 2024. No sign of an incumbent lobbying push at this agency.
No lobbyist on these filings lists a past U.S. Coast Guard (USCG) job: no revolving-door tie found in these filings. (These are lobbyists the companies pay, not their own staff.)
None of these winners matched a listed company, so PAC and FARA checks did not run.
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
No bills named on these filings under Coast Guard-related issues.
A bill's title is shown only when the filing's own text names it; filings often cite last Congress's bill numbers.
No executive order in the last 12 months names Coast Guard in its title or summary.
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.
None of the past winners matched a listed company.
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name, including the subsidiaries a company lists in its SEC filings. A company we could not match shows no market rows; that is a miss, not a finding.