Combined Synopsis/SolicitationPosted Sep 16, 2026·Responses due Sep 22, 2026

Fourier Transform Infrared Spectrophotometer (FTIR)

FDA · FDA OFFICE OF ACQ GRANT SVCS

Stage
Open solicitation
NAICS
334516
Value
Not stated
Solicitation
75F40126Q00406
Set-aside
No Set aside used
PSC
6640
Place
San Juan, PR, USA
Contact
Pamela T. Lee (pamela.lee@fda.hhs.gov)
Loading your pipeline and notes…
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation 75F40126Q00406 in this department, oldest first.

Early notice
None posted
Solicitation
  • Sep 16, 2026 · this notice
    Combined Synopsis/Solicitation
Award
Not yet. Too few past cases at this agency to estimate timing (6 found; 10 needed).

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Decide bid or no bid before the response deadline.
  • Look at the past winners for likely competitors and teaming partners.
  • Follow the opportunity to hear about amendments and the award.

What the notice says

Statement of Work (SOW) Fourier Transform Infrared Spectrometer (FTIR) for the San Juan Medical Products Laboratory Background The Food and Drug Administration (FDA), San Juan Medical Products Laboratory (SJNLMP) needs to replace an existing Fourier Transform Infrared Spectrometer (FTIR) system used for routine sample identification analysis with a new Fourier Transform Infrared Spectrometer (FTIR System. The system in use needs to maintain cGMP/cGLP, ISO/IEC 17025-2017, ISO 9001:2008, and 21 CFR 11 standards for use as analytical equipment under the current accreditation. The system is used t… (show all)

o analyze medical product samples using specific protocols and methods established by USP, internal FDA, DOD SLEP, and the FCC program. As a Medical Product Specialty Laboratory, the laboratory uses FTIR technology to analyze and provide specific identification to a variety of drug samples. The San Juan Laboratory needs to update the existing 17-year-old FTIR to a new system with modern capabilities, software, and instrument components. The older FTIR system is no longer supported by the manufacturer, is out of service and in need of repairs, and is no longer functioning as intended. In addition, the hardware shows internal system rust and lens fogging, increasing maintenance cost, posing analytical failures and instrument malfunction. The newer Fourier Transform Infrared Spectrometer (FTIR) includes part warranties for up to 10 years and comes with newer software and instrument controller. Objectives To obtain a fully functional modern Fourier Transform Infrared Spectrometer (FTIR) with improved analytical capabilities to replace a 17-year-old FTIR system. Scope The Contractor shall provide all resources necessary to accomplish the tasks and deliverables described in this Statement of Work (SOW). One FTIR system to replace an older FTIR system. Requirements All the following system requirements are minimum requirements: � The Fourier Transform Infrared Spectrometer (FTIR) shall comply with the following quality requirements: ISO/IEC 17025-2017 https://www.iso.org/standard/39883.html, https://www.iso.org/standard/66912.html ISO 9001:2008 https://www.iso.org/standard/46486.html 21 CFR Part 11 Compliance https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/cfrsearch.cfm USP, cGMP/cGLP https://login.usp.org/cas/login?service=http%3A%2F%2Fonline.uspnf.com%2Fcas%2Flogin Instrument controller firmware, drivers, and updates must be compatible with the current laboratory domain system. � The FTIR system shall include the following salient requirements: Optical System shall include the following specifications: Spectral range: 8,000-350 cm-1 Spectral resolution: Better than 0.45 cm-1. Signal-to-Noise Ratio: 40,000:1. Wavenumber Precision: 0.001 cm?� at 2,000 cm?�. Sealed and desiccated optical unit. Detector: Thermoelectrically cooled (TEC) DTGS. Interferometer with KBr/Ge mid-infrared beamsplitter. Source: Single-point source with 10-year warranty. ATR with XR Diamond Crystal Plate shall include the following specifications: Spectral Range 7800 � 350 cm-1 Traceable polystyrene ATR standard The system shall include a Desiccant Replacement Kit. The system shall include Purge Kit. � Hardware and Connectivity shall include the following salient requirements: Integrated touchscreen Integrated LightBar status. Ethernet connection Monitor 22� Wireless Keyboard and Mouse Windows 10 The system shall include the current Instrument Controller Software with: Data Acquisition & Analysis Spectral Processing Library Instrument License Current Instrument Firmware � Warranty: The entire system shall be warrantied for parts and labor for a minimum of 1-year limited warranty from date of formal government acceptance. The Diamond ATR shall be warrantied for 5 years. The source, laser, and interferometer shall be warrantied for 10-years. � Delivery, Installation and Service Onsite installation of the entire system shall be included and inclusive of labor, delivery, and travel costs. Inside delivery, set up, installation, and clean-up of the area at the place of performance is required. The systems shall be delivered with all necessary supplies and accessories required for installation and start-up. Standard kits for operational qualification and performance verification (OQ/PV) shall be included. Installation of hardware & software shall be conducted by factory-certified service personnel. The vendor shall demonstrate upon installation that the system meets or exceeds all performance specifications which have been included in the vendor�s response and/or used as evaluation criteria for award. The following shall be demonstrated at the time of installation: The contractor shall demonstrate that all modules start up properly, are correctly installed and connected. Shall include Hardware IQ/OQ with Performance Verification. Shall include Software IQ/OQ and testing of basic functional specifications and Chapter 21 CFR part 11. The vendor shall provide IQ/OQ electronic documentation of Software and Hardware. The vendor shall include a minimum of one preventative maintenance visit for the KFT to ensure the instruments are functioning at peak performance. The vendor shall include shipping to Puerto Rico. � Training: Onsite familiarization training for 3-5 users shall include basic system operation and routine maintenance. Trade and Service Specs � Equipment shall be newly manufactured, not used, refurbished, or previously used for demonstration. � The Contractor shall provide a minimum of a one-year manufacturing warranty for all manufactured equipment and parts. Ten-year warranty on source, laser, and interferometer. The warranty shall be included with the equipment and not separately priced. The warranty shall include at a minimum: coverage on all non-consumable items and parts supplied including base instrument, factory-certified replacement parts, engineer labor and travel costs. Any equipment repair and maintenance work shall be performed by an OEM-trained engineer. This factory-trained engineer shall have (verified by the OEM) the following: 1) access to OEM factory telephone support; 2) access to the most current OEM factory training for both hardware and software components; and 3) access to all current OEM factory parts, not build-to-order parts. The OEM-trained service engineer shall not use salvaged parts from other instruments for performing maintenance and repairs. All parts used in PM and repairs must be guaranteed, factory-tested, OEM quality parts. � Instrument operators shall have access to a technical representative call center at no additional charge, for technical assistance and troubleshooting, which is staffed by senior engineers to provide a high level of expertise for troubleshooting the instrument. � The supplier shall provide training and validation of the equipment and software on site at the time of installation. Sufficient familiarization training for 3-5 users per delivery onsite location will be provided, such that operators may independently operate the instrument and with increased familiarity and proficiency. The training shall include manuals and any consumables to be used during training. � The Contractor shall provide installation qualification with an employee who can provide proof of installation qualification/operation qualification (IQ/OQ) certification. The qualification and verification report shall include the standard operating procedures and the allowed manufacturer limits for the instrument. A copy of the calibration report and the qualification and verification report(s) shall be reviewed and approved by an FDA representative before installation of the equipment and execution of protocols. � Inside delivery, disposing pallets, boxes, and any associated garbage, and unpacking the equipment and inventory of parts with a lab representative. Deliverables or Delivery Schedule Deliverable Quantity Due Date FTIR (Fourier Transform Infrared Spectromete

Who won similar work

4 award notices on SAM.gov in the last 24 months. Matched by: Same office (FDA OFFICE OF ACQ GRANT SVCS), same product/service code (PSC) 6640.

Single-winner award sizes (4): middle half $323K to $416K, median $397K; range $123K to $454K.

WinnerAwardsValueLast
TURBOFIL PACKAGING MACHINES, LLC1$454KSep 24, 2026
CAPITOL CARBONIC CORP1$403KJan 6, 2025
Atlantic For Services Inc1$390KJan 2, 2025
Z-SPEC, INC.1$123KAug 21, 2026

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in. Revenue next to a ticker is the company's last annual revenue from its 10-K.

Latest awards

Competitive landscape

For the 4 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 0 of these past winners lobbied Food & Drug Administration (FDA) since 2024 (0 filings)
  • 0 of their lobbyists list a past Food & Drug Administration (FDA) job
  • No corporate PAC money from them to the overseeing committees since 2024
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 0 bills named on the past winners' lobbying filings
  • 129 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.

  • 0 of the past winners are listed companies
  • 0 insider buys and 0 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.