Award NoticePosted Mar 25, 2026

6632--Automated Osmolality Testing

Veterans Affairs · 248-NETWORK CONTRACT OFFICE 8 (36C248)

Stage
Awarded
NAICS
334516
Value
$148K
Solicitation
36C24826Q0407
Set-aside
None stated
PSC
6632
Place
Not stated
Contact
David Griganavicius (david.griganavicius@va.gov)
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation 36C24826Q0407 in this department, oldest first.

Early notice
  • Mar 10, 2026
    Pre-solicitation
    Open
Solicitation
  • Mar 10, 2026
    Solicitation
    Open
  • Mar 10, 2026
    Solicitation
    Open
  • Mar 18, 2026
    Solicitation
    Open
Award
  • Mar 25, 2026 · this notice
    Award Notice
    STRIPES GLOBAL, INC. · $148K

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Note the winner and the end of the period of performance for the recompete.
  • Follow the agency to see the next notice for this work.

What the notice says

Statement of Need: Automated Osmometer CPT SCOPE: The Contractor shall provide a two (2) fully automated Osmometer System, including, delivery, installation, training, reagents, consumables for the Tampa VA Healthcare Network (TVAHCN), Department of Pathology and Laboratory Medicine Service (P&LMS) located at 13,000 Bruce B. Downs Blvd., Tampa, Florida 33612. All work is to be performed in accordance with the guidelines established by Federal, State, and local ordinances. FDA and manufacturer's guidelines, with all terms, conditions, provisions, schedules, and specifications provided herein. T… (show all)

he Contractor selected is responsible for system installation, maintenance coordination and supply procurement for all equipment. GENERAL REQUIREMENTS: The contractor is required to furnish all of the following: All reagents and supplies necessary to operate the contractor's equipment, including calibrators and or calibration material, reagents, linearity testing material, at least 2 levels of test control material, disposables, consumables, cleaning solutions, diluent solutions, sheath fluids, and any instrument part required for operating all analyzers and equipment. ADDITIONAL NOTES: Contractor shall provide enough reagents sufficient to perform testing at each location for a minimum of 30 days. Reagent quality must be high enough to satisfy proficiency testing of the College of American Pathologists and the Joint Commission. Contractor to provide all reagents, calibrators, and controls needed along with technical assistance to perform correlation studies from a single lot at no additional cost for new test methods or changes in test menus. (i.e., Contractor is to provide all manpower and reagents/supplies to do correlation studies). Equipment must be able to Interface to the Lab Information System (Vista) / middleware (Data Innovations). All consumables and user-defined replacement parts necessary to operate the contractor's equipment, including secondary, aliquot tubes. On- and/or Off-site training for end users and key operators. Delivery and installation of equipment at no additional charge as well as return shipping costs at end of contract (removal). Contractor to perform equipment and assay installation including full validation of system hardware and software as well as assay performance studies as applicable (assay correlations to existing instrumentation, carryover, linearity, dilution validation, precision, accuracy, reference range studies, and normal range studies). Accuracy studies for each analyte. A minimum of 30 samples, spanning the reportable range, will be run by the present and the new contracted method. Contractors will analyze numbers and provide statistical data to accept the new method. Statistics will consist of at least mean, bias, slope, y-intercept, correlation coefficient, analysis, and meet current standards defined by CLSI. Linearity analysis will be performed on new contracted instrument(s) for each analyte to determine reportable range. A 5-point linearity analysis that adheres to the Beer� Lambert Law should be performed as a minimum. Precision study utilizing normal and abnormal control material will be performed. This should consist of a within run precision study of 10 normal and 10 abnormal controls and a day-to-day precision study of normal controls and abnormal controls for 10 days (may be run twice a day) for a total of 20 values per level of control. Calibration verification will be performed using samples of known value. These can be calibrators or CAP assayed survey samples, or equivalent. Sensitivity: Sensitivity may be validated concurrently with the linearity verifications. Reference Range: Determine a reference range for each analyte following CLSI guidelines. Samples used for the reference range study shall be representative of the patient population being tested. Reference range assessment shall be performed for each lab. One of the following protocols should be used: A verification of the manufacturer's suggested reference range may be performed as long as the suggested range is based on a comparable population of test subjects. The manufacturer shall provide specific information defining how the suggested range was determined. A minimum of 20 reference individuals shall be used to verify the manufacturer's range. Any apparent outliers should be discarded and new specimens obtained to provide a statistically valid verification. If the suggested manufacturer's range is not appropriate for the patient population, a reference range shall be established. Establishing a reference shall follow CLSI guidelines. This requires a minimum of 120 reference individuals be used to establish a reference range. The reference interval should be determined using the nonparametric method. If a laboratory is currently using the proposed instrument/reagent system, the "in-use" reference range can be transferred to the "new" system if a method comparison study between the two systems proves to be acceptable. If comparison studies are not acceptable, then an alternate test shall be provided. Therapeutic range validation studies shall be performed by Contractor for applicable analytes, using CLSI guidelines. Carryover studies shall be performed, as applicable, as part of the initial evaluation of the instrument. Contractor will provide interpretation of raw data for each instrument installed and validate no carryover exists within the test platforms. All technical procedures shall be provided by Contractor on diskette in CLSI format, using software compatible with each Laboratory's computer system, for local modification to meet CAP requirements. All shipping costs for reagents, consumables, supplies and equipment (install and removal at the end of contract) including delivery to the clinical laboratory at all sites. Note: includes emergency, overnight delivery as necessary. Special handling for emergency orders of supplies: If the supplies are found to be defective and unsuitable for use with the Contractor s equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery with no shipping expenses. EQUIPMENT SYSTEM TECHNICAL SPECIFICATIONS AND FEATURES: The vendor must provide: One (1) Advanced Instruments OsmoPRO® MAX Automated Osmometer One (1) Advanced Instruments Osmo1® Single-Sample Micro-Osmometer Redundant equipment must use the same reagents, controls, calibrators, and consumables, and provide the same reference ranges. General System Requirements OsmoPRO® MAX Automated Osmometer: All equipment provided must be new. Dimensions (W x D x H): 14.0 x 16.5 x 18 (+ or 2 inches in any direction). Electrical voltage: 100 to 240 VAC (50/60 Hz) Operating Conditions (must operate ranges below or better): Temperature 18°C to 35°C (64°F to 95°F); 5 to 80% relative humidity (non-condensing) Sample type: Serum, plasma, and urine Sampling must be from the primary tube, no pipetting or aliquoting required Measurement Principle: Freezing point depression Minimum Required Sample Volume: 190 L Sample Capacity: Must support continuous loading of at least 500 samples or more. Resolution: 1 mOsm/kg H2O Range: 0 to 2000 mOsm/kg H2O Display: Touchscreen with onboard video instructions Memory capacity: 1,000 results / 10,000 events (+ or 5% for ea

Who won similar work

13 award notices on SAM.gov in the last 24 months. Match: Same office, same NAICS 334516.

WinnerAwardsValueLast
POLYMEDCO CANCER DIAGNOSTIC PRODUCTS LLC3$4.4MApr 22, 2026
GOVERNMENT SCIENTIFIC SOURCE INC2$3.8MMay 27, 2026
CEPHEID SUNNYVALE 940892$843KOct 5, 2026
SEBIA, INC.1$3.6MMay 4, 2026
ABBOTT LABORATORIES INC. · $ABT1$3.4MApr 27, 2026
Fisher Scientific Company · $TMO1$2.7MMar 31, 2026
BECKMAN COULTER, INC.1$1.4MMar 12, 2026
HOLOGIC SALES AND SERVICE, LLC1$245KMay 4, 2026
FRANKLIN YOUNG INTERNATIONAL, INCORPORATED1$83KOct 1, 2025

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.

Latest awards

Competitive landscape

For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 2 of these past winners lobbied Veterans Affairs, Dept of (VA) since 2024 (6 filings)
  • 0 of their lobbyists list a past Veterans Affairs, Dept of (VA) job
  • $88K from their corporate PACs since 2024 to members of House Committee on Appropriations, House Committee on Veterans' Affairs, Senate Committee on Appropriations, Senate Committee on Veterans' Affairs
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 8 bills named on the past winners' lobbying filings
  • 25 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.

  • 2 of the past winners are listed companies
  • 0 insider buys and 9 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.