6540-- 541-26-3-2611-0455 - PowerRef 3 System Hardware/Software
Veterans Affairs · 250-NETWORK CONTRACT OFFICE 10 (36C250)
Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.
Where this opportunity stands
Every notice posted under solicitation 36C25026Q0950 in this department, oldest first.
- Aug 27, 2026 · this noticeSources Sought
Next steps for this stage
Standard steps for the notice type; not advice about this buyer.
- Answer the notice: this is when the requirement can still be shaped.
- Contact the contracting officer named on the notice.
- Check who won similar work; they are the likely bidders.
What the notice says
SOURCES SOUGHT NOTICE THIS REQUEST FOR INFORMATION (RFI/Sources Sought) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a). DISCLAIMER This request for information, sources sought (RFI/Sources Sought) is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in … (show all)
response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 10.002(b)(2), FAR 12.101, FAR 12.103 & FAR 12.202(a), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified Small Businesses under NAICS 339112, (Surgical and Medical Instrument Manufacturing industry), but does not exclude others from responding. Responses to this source sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this source sought, a solicitation announcement may be published. Responses to this source sought synopsis are not considered adequate responses for a solicitation announcement. SOURCES SOUGHT DESCRIPTION The Department of Veterans Affairs, Network Contracting Office 10, Louis Stokes Cleveland VA Medical Center, is seeking sources that can provide a Accommodation Meter plusoptiX R09 (PowerRef 3) and accessories for Surgical Department Mechanical Room that meets the following: Product/Items ITEM NO. DESCRIPTION QUANTIYT UNIT OR STOCK NO. Request purchase only of Accommodation Meter plusoptiX R09 (PowerRef 3) Accommodation Meter plusoptiX R09 (PowerRef 3) incl. Medical Power Adaptor 1 EA 2. Software Licence RP Dynamic measurements of accommodation in sphere, convergence and pupil size changes in scotopic, mesopic and photopic conditions 1 EA 3. Complete measurement set-up kit (includes former MIRROR, SLIDE and REST) 1 EA 4. Shipping and Handling 1 EA Specifications & Salient Characteristics Technical Specifications Refraction (vertical meridian): Binocular and monocular measurement Spherical range: +5.00 D to 7.00 D, in increments of 0.01 D Pupil size: Range: 4.0 8.0 mm, measured in 0.1 mm steps, ±10% accuracy Pupil distance (interpupillary distance): Measured in 1.0 mm steps, ±10% accuracy Sampling rate: 50 Hz (one measurement every 20 ms) Measuring distance: Standard working distance of 1 m (± 5 cm) Measurement principle: Binocular, dynamic photoretinoscopy Interfaces & Power Requirements Interfaces: 4 × USB ports 1 × VGA output (supports 1024 × 768 resolution) Power supply: AC 100 240 V, 50 60 Hz, 2.5 A (excluding monitor) Environmental Conditions Operating temperature: 10 35 °C (50 92 °F) Storage temperature: 0 50 °C (32 122 °F) Relative humidity (non-condensing): Operating: 20 80% Storage: 10 85% Data Output & Logging Measurements are continuously recorded into a CSV logfile, capturing: Timestamp (every 20 ms) LED brightness (percentage) Pupil detection status (found/not found) Pupil size (width & height in mm) Pupil brightness (digital units 0 255) Purkinje reflex size & position (pixels: X & Y) Gaze angles (horizontal & vertical in degrees) Spherical refraction per eye, including mean & standard deviation over last 10 frames Interpupillary distance in mm Camera horizontal angle Salient Functional Characteristics Binocular dynamic measurement: Tracks continuous changes in accommodation (sphere), convergence, and pupil size for both eyes 50 Hz real-time sampling: High temporal resolution enables precise tracking of fast dynamics Open-field fixation: Uses a hot mirror to allow naturalistic visual targets at any distance Non-contact operation: Measurements gathered without touching the subject Research-grade device: Designed specifically for scientific applications investigating accommodation response times, IOL performance, convergence accommodation relationships, and neuro-ophthalmologic metrics Integration & Output Data can be streamed via USB or recorded to a VGA-connected monitor Outputs are ideal for integration into custom research setups and signal logging systems Salient Characteristics Plusoptix PowerRef 3 Accommodation Measurement System The PowerRef 3 system must meet the following minimum salient characteristics to satisfy clinical research and operational requirements for binocular, real time accommodation and convergence measurement: 1. Measurement Capability Must perform simultaneous binocular measurement of: Refractive state (sphere, vertical meridian) Convergence/vergence Pupil size (both eyes) Must provide continuous, real time data acquisition suitable for dynamic accommodative and vergence analysis. 2. Sampling and Data Output Must provide a minimum sampling rate of 50 Hz (20 ms intervals) to capture rapid accommodation fluctuations. Must support continuous data streaming and export to external computers and research software. Must allow real time or recorded output in spreadsheet compatible formats. 3. Optical and System Design Must use infrared photorefraction technology. Must include an open field optical design, enabling natural fixation on targets at varying distances without the constraints of an enclosed optical path. Must incorporate a hot mirror target presentation system permitting both stationary and moving fixation stimuli at adjustable distances. 4. Calibration and Reliability Must be engineered for long term calibration stability, requiring no routine recalibration under normal use. Must include durable optics and electronics suited for repeated daily research use. 5. Fixation Target Flexibility Must support user selectable fixation targets, including moving or adjustable distance stimuli for controlled accommodation and vergence testing. 6. Integration and Compatibility Must be compatible with standard Windows based data acquisition systems, research platforms, or laboratory PCs. Must allow USB or networked connection for external data handling. 7. System Configuration Must include all necessary hardware, software, cables, and accessories required for full operational use upon installation. Background: The VA-ORD-funded study Home-based Treatment of Binocular Eye Dysfunction in Veterans with Traumatic Brain Injury (Mark Walker, M.D., principal investigator) will investigate physiological mechanisms underlying near vision impairment in Veterans and will conduct a pilot study to explore the feasibility and potential efficacy of virtual-reality for customized home therapy of convergence insufficiency. This study requires robust measures of ocular accommodation, the change in the shape of the eye s lens to focus on near images. For that purpose, we require a device that can measure directly changes in lens curvature and that can do this dynamically at a high enough sample rate to measure not only the amount but also the rate of accommodation. The device must also have integrated eye tracking for simultaneous measurement of ocular vergence. The PlusOptix PowerRef3 is the only currently available device that measures accommodation directly and dynamically, is portable, and includes eye tracking to measure simultaneous convergence. Scope: Acquisition� of an automated� retinoscopy-based accommodation and ocular vergence measurement device, its� control� software, and� associated� measurement apparatus.� � � The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested p
Who won similar work
115 award notices on SAM.gov in the last 24 months. Match: Same office, same NAICS 339112.
| Winner | Awards | Value | Last |
|---|---|---|---|
| Edwards Lifesciences LLC · $EW | 51 | $1.7M | Oct 7, 2026 |
| VETERANS HEALTHCARE SUPPLY SOLUTIONS, INC | 9 | $559K | May 21, 2026 |
| LOVELL GOVERNMENT SERVICES INC. | 7 | $202K | Jun 23, 2026 |
| SCRIPTPRO USA INC | 5 | $1.1M | Sep 18, 2026 |
| Omnicell, Inc. · $OMCL | 4 | $2.2M | Jul 24, 2026 |
| TERUMO MEDICAL CORP | 4 | $121K | Jul 2, 2026 |
| RADFORMATION, INC | 3 | $299K | Aug 28, 2026 |
| RED ONE MEDICAL DEVICES LLC | 3 | $173K | Jul 14, 2026 |
| GEO-MED, LLC | 3 | $100K | Jul 7, 2026 |
| Trillamed LLC | 2 | $1.1M | Jul 28, 2026 |
Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.
- Oct 7, 2026Edwards Lifesciences LLC$34K6515--SUPPLY-HEART VALVE- INDIANAPOLIS
- Sep 18, 2026SCRIPTPRO USA INC$327KScriptPro Equipment
- Sep 17, 2026Edwards Lifesciences LLC$34K6515--SUPPLY-HEART VALVE- INDIANAPOLIS
- Sep 16, 2026Edwards Lifesciences LLC$34K6515--SUPPLY-HEART VALVE- INDIANAPOLIS
- Sep 3, 2026COVIDIEN SALES LLC$115K36C25026P0866 Manometry Probes SPS - Cincinnati PO 539A60196
- Aug 28, 2026RADFORMATION, INC$64K6515--Software - Emergency Radformation - Detroit
- Aug 19, 2026Edwards Lifesciences LLC$34K6515--SUPPLY-HEART VALVE- INDIANAPOLIS
- Jul 30, 2026SCRIPTPRO USA INC$175K6515--Equipment - Automated Will Call Device - Indianapolis
- Jul 28, 2026Trillamed LLC$400K6515--EQUIPMENT, OMNICELL IVX, Detroit
- Jul 24, 2026Omnicell, Inc.$340K4110--Equipment, MedChill Refrigerator - Pharmacy, Ann Arbor
Competitive landscape
For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
- 1 of these past winners lobbied Veterans Affairs, Dept of (VA) since 2024 (4 filings)
- 0 of their lobbyists list a past Veterans Affairs, Dept of (VA) job
- $8K from their corporate PACs since 2024 to members of House Committee on Appropriations, House Committee on Veterans' Affairs, Senate Committee on Appropriations, Senate Committee on Veterans' Affairs
- 0 foreign-agent (FARA) registrations
Policy around it
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
- 0 bills named on the past winners' lobbying filings
- 25 rules from the department in the last 12 months
- 0 executive orders naming the agency in the last 12 months
Market
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.
- 2 of the past winners are listed companies
- 0 insider buys and 10 insider sells at them in the last 90 days
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.