Combined Synopsis/SolicitationPosted Aug 31, 2026·Responses due Sep 3, 2026

PLOW PUSHER 3056 JRB 420 XHD RUBB BLTEND

Army Mission and Installation Contracting Command (MICC) · W6QM MICC-FT DRUM

Stage
Open solicitation
NAICS
336999
Value
Not stated
Solicitation
W911S226U4159
Set-aside
None stated
PSC
3590
Place
Not stated
Contact
Carrie Lawton (carrie.l.lawton.civ@army.mil)
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation W911S226U4159 in this department, oldest first.

Early notice
None posted
Solicitation
  • Aug 19, 2026
    Combined Synopsis/Solicitation
    Open
  • Aug 31, 2026 · this notice
    Combined Synopsis/Solicitation
  • Aug 31, 2026
    Combined Synopsis/Solicitation
    Open
Award
Not yet. Typical award: Sep 14, 2026 to Oct 24, 2026, middle of the range Sep 30, 2026.
Measured from 1578 past solicitations at Dept of the Army that later posted an award (middle half of cases, counted from Aug 19, 2026).

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Decide bid or no bid before the response deadline.
  • Look at the past winners for likely competitors and teaming partners.
  • Follow the opportunity to hear about amendments and the award.

What the notice says

The plow shall be a pusher plow with a 30-foot blade and with the top of the inside barrel being 56 inches from the ground. The plow shall have an integrated weld-in JRB 420 coupler, with each inner face measuring 29 3/8 inches from each other, and evenly spaced from the center. The end plates shall be made from 3/8-inch plate and shall be a maximum of 61 11/16 inches tall and maximum width of 41 3/8 inches. There shall be (3) square 11/16-inch holes with the centers positioned 3 inches, 19 inches, and 35 inches away from the front side of the plate, and 2 inches from the bottom of the plate. … (show all)

Each end plate shall have a 2 1/2-inch section at the end of each plate which will be bent away from the plow weldment. Each end plate shall have a 1 1/2-inch hole positioned at the top of the plate. There shall be (7) 9/16-inch holes on each end plate along the profile of the final rib to attach the end plate to the plow weldment. The end plate shall attach to the plow weldment with (7) 1/2-13 x 2-inch Grade 8 hex bolts and (7) 1/2-13 Grade 8 locknuts. On each end plate shall be welded (2) identical support gussets made from 3/8-inch plate measuring 2 1/2 inches x 32 inches. On each end plate will be a shoe weldment with a mounting plate constructed from 1/2-inch steel, a base plate made from 3/4-inch steel, and (2) 1/2-inch x 4-inch x 4-inch gussets each positioned 11 1/2 inches from the center. The shoe shall be 6 3/4 inches tall, measure 39 11/16 inches in length, and be 6 inches in depth. There shall be (3) mounting slots positioned at the center and 16 inches from the center measuring 11/16 inches in width and measuring 2 3/8 inches in length. The mounting shoe shall be secured to each end plate with (3) sets of a 5/8-11 Grade 8 bolt, a 5/8 Grade 8 washer, and a 5/8-11-inch Grade 8 locknut. The plow skin shall have (7) press-broken brakes to form the plow, with (2) additional brakes at the top to form the box brake. The plow skin shall be a total of 360 1/2 inches wide, formed from (3) 8GA segments measuring 90 quarter-inches (or 90 1/4 inches) in length, and having an original height of 84 1/2 inches. There shall be (14) drain holes on the brake between the plow skin and the box brake, burnt at 9/16 of an inch. There shall be (38) slots in the bottom of the plow skin to facilitate the attachment of the blade. There shall be (2) 1 1/2-inch x 10-inch x 180-inch rubber blades attached to the plow skin. The blade will be secured via (6) 3/8-inch x 3-inch x 57-inch retainer plates and (34) 5/8-11 x 4-inch Grade 8 bolts with 5/8-11 Grade 8 locknuts. There shall be (15) ribs placed vertically on the plow skin for support made with 1/2-inch plate. On the outermost ribs shall be (7) mounting holes for the end plates. The innermost (2) ribs shall be shorter in length and weld to the couplers. The 2nd outermost set of ribs shall have a 2 1/2-inch diameter hole positioned at the top. There shall be one rib positioned between the couplers with a 2 1/2-inch hole at the top for lifting. Between each rib on the rear of the plow shall be a section of 5-inch x 5-inch x 1/2-inch angle placed between the 3rd and 4th brakes from the bottom of the skin. (12) shall be 24 inches in length, with the angles (2) in the center being 14 5/16 inches in length. Below the first brake shall be (4) identical pieces of bent reinforcement placed end to end measuring 3/8-inch x 18-inch x 89 13/16-inches, which shall cover the entire length of the plow. Below all ribs excluding the outer 4 and the center shall be lower ribs whose profile shall encircle the bent channel and terminate in a flat section perpendicular to the ground. These lower ribs will have additional supports on the bottom, and between the ribs/couplers and the couplers themselves. The supports and lower ribs will all be welded to (2) 124 11/32-inch x 19 3/4-inch reinforcement plates, one on either side, with 1 3/8-inch x 12 29/32-inch slots spaced 14 19/32 inches from the center to accommodate the weld-in couplers. All of these supports will be made from 3/8 plate. Connecting the outermost lower ribs and the end plate will be (4) outer lower reinforcements, (2) per side. The lower of these supports on either side shall be supported via a 1/2-inch x 6-inch x 8 1/2-inch plate welded to the skin, lower reinforcement, and blade angle. At each corner of the plow shall be a triangular gusset for reinforcement, made from 3/8-inch plate at the bottom of the plow and 8GA at the top. Between the couplers shall be (2) 1/2-inch x 6-inch x 6-inch gussets. The blade angle shall be a 6-inch x 4-inch x 3/4-inch x 360-inch angle with 38 holes spaced along its length. It will also have (27) 1/2-inch x 2 1/4-inch x 4-inch gussets spaced between the holes.

Who won similar work

13 award notices on SAM.gov in the last 24 months. Match: Same office, same NAICS 336999.

WinnerAwardsValueLast
LOGISTICS365 INC3$180KAug 21, 2025
NASSAU CABLE CORP1$207KAug 21, 2025
TECH SERVICE SOLUTIONS LLC1$99KJun 3, 2025
NR FRAGRANCES & COSMETICS INC1$97KSep 9, 2025
ALL AROUND ACCESS, LLC1$56KAug 26, 2025
AANTILIA LLC1$55KMar 3, 2025
Suncore Distribution LLC1$33KAug 14, 2025
Gage R Buchli Grand Forks ND 58201 USA1$33KJul 7, 2025
MAHUYA INDUSTRIES, LLC1$31KAug 18, 2025
TALLGRASS SOLUTIONS, INC.1$25KAug 26, 2025

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.

Latest awards

Competitive landscape

For the 8 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 0 of these past winners lobbied Army, Dept of (Corps of Engineers) or Army, Dept of (Other) or Natl Guard since 2024 (0 filings)
  • 0 of their lobbyists list a past Army, Dept of (Corps of Engineers) or Army, Dept of (Other) or Natl Guard job
  • No corporate PAC money from them to the overseeing committees since 2024
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 0 bills named on the past winners' lobbying filings
  • 32 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.

  • 0 of the past winners are listed companies
  • 0 insider buys and 0 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.