SolicitationPosted Mar 25, 2024·Responses due Apr 10, 2024

Z1NE--405-23-001 | Water Tank Painting and Repair

Veterans Affairs · 241-NETWORK CONTRACT OFFICE 01 (36C241)

Stage
Open solicitation
NAICS
238320
Value
Not stated
Solicitation
36C24123R0112
Set-aside
None stated
PSC
Z1NE
Place
Not stated
Contact
Michael D Crafts (Michael.Crafts@va.gov)
Loading your pipeline and notes…
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation 36C24123R0112 in this department, oldest first.

Early notice
  • Feb 23, 2024
    Pre-solicitation
    Open
Solicitation
  • Feb 23, 2024
    Solicitation
    Open
  • Feb 23, 2024
    Solicitation
    Open
  • Mar 25, 2024 · this notice
    Solicitation
  • Mar 28, 2024
    Solicitation
    Open
  • Aug 13, 2024
    Solicitation
    Open
Award
  • Jan 7, 2025
    Award Notice
    RAZORBACK LLC · $377K
    Open

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Decide bid or no bid before the response deadline.
  • Look at the past winners for likely competitors and teaming partners.
  • Follow the opportunity to hear about amendments and the award.

What the notice says

1 NOTICE OF FOR PROPOSAL AMENDMENT SOLICITATION NUMBER: 36C24123R0112 AMENDMENT NUMBER: 0003 DATE: March 25, 2024 PROJECT NUMBER: 405-23-001 PROJECT TITLE: Water Tank Painting and Repair LOCATION: VA Medical Center, White River Junction, VT 05009 REASON FOR AMENDMENT: Answer RFI Questions 1 thru 13 & Extend Proposal Deadline ___________________________________________________________________________ AMENDMENT: 0003 Question 1 SOW states Contractor shall provide two temporary water storage tanks, each holding at least 6,000 gallons. Tanks shall be piped together and tied into the water service … (show all)

and distribution lines. The temporary water storage tanks shall be able to hold at least 70 PSI of water pressure Using tanks that are 6,000 gals and able to handle at least 70 psi of pressure is tall order. Those type of tanks are very expensive at that size. Is it possible to use static tanks with temporary pumps that could be triggered from the BMS? VA Response:� � Yes, that would be fine. The tanks are intended to be used as a temporary tower. The 70 PSI will be maintained with the water pumps in building 2. The VA intends to have the water service flow through the tanks to keep the stored water fresh. The tanks will be wired into the BMS system at the water tower. The BMS is a Siemens Desigo Building Automation system. Question 2 SOW states Water tanks shall be wired into the Building Management System (BMS) to communicate with the two VFD water tower supply pumps in building 2 to maintain a full condition. The water tanks will serve as a temporary water tower, providing an emergency supply of water to the campus in case of any failure by the municipal water system. We are not quite clear on what is needed and how to integrate the tanks into the BMS. What needs to be integrated ? Is it the pressure and / or levels? VA Response:� A level indicator needs to be on the tanks to be sure they remain full. Question 3 Since the opportunity was changed from SDVOSB set aside to small business set aside, will the VAAR evaluation factors for SDVOSB/VOSBs be included 852.215-70 Service-Disabled Veteran-Owned and Veteran-Owned Small Business Evaluation Factors? VA Response:� � No. Question 4 The solicitation documentation (SOW, section 3 Task & Requirements, number 12) contains a reference to completing the work in compliance with the Vermont Department of Environmental Conservation, Drinking Water and Ground Water Protection Division VA Hospital Permit to Operate (WSID 12037) dated 6/6/17 . Will you please provide a copy of this document? VA Response:� � Yes. See attachment. Question 5 For exterior pressure washing, are we required to capture water or allow it to run to the ground as long as we collect paint chips and other debris? VA Response:� � Water is not required to be captured, as long as paint chips and other debris is collected. Question 6 Are there any as-builts showing details of the tank itself (e.g., detailed schematics for the tank, ladders, walkways, hard points that we can rig from, etc.) If so, will you please provide? VA Response:� � Yes. See attachment. Question 7 Please confirm the Site Safety and Health Officer (SSHO) may also be the production supervisor. VA Response:� � As long as both roles can be performed fully successfully, they may be managed by a single person. Question 8 Section 13 90 00 2.01.B. of the spec calls out Tnemec as basis of design and states that product by Jotun and Hempel coatings will also be considered if they meet the performance criteria. Will alternate manufacturers (e.g., Sherwin Williams, PPG, Carboline) be deemed acceptable if they meet the performance criteria? VA Response:� � Yes, alternative manufacturers will be deemed acceptable if they meet performance criteria. Question 9 Section 13 90 00 3.01.B.1 calls out SSPC SP-11 Power Tool Cleaning to Bare Metal for all repair areas. Please confirm this is only for heavily rusted areas and that areas with sound coating are to be pressure washed in accordance with SSPC WJ-4 Low Pressure Water Cleaning in advance of overcoating. VA Response:� � Correct. Question 10 No alternate for exterior surface prep and coating including full abrasive blast and recoat found in the specification. Please advise if this alternate price is to be provided. VA Response:� � No alternate line items are proposed. Question 11 Will owner provide water at no charge for disinfection following coating scope of work? VA Response:� � Yes. Question 12 Please confirm the third party inspector shall be at a minimum NACE CIP Level 1. (SOW, section 3 Task & Requirements, number 24B). VA Response:� � NACE Level 1 inspector may be used to monitor the painting and cleaning and ensure compliance with the specifications. But the onsite NACE Level 1 inspector must be supported by a NACE Level 3 inspector to assist with technical support and quality control. Question 13 Are we required to fence the project area? VA Response:� � No, access to natural gas plant needs to remain accessible.

Who won similar work

4 award notices on SAM.gov in the last 24 months. Matched by: Same agency (Veterans Affairs), same product/service code (PSC) Z1NE.

Single-winner award sizes (4): middle half $192K to $500K, median $313K; range $22K to $867K.

WinnerAwardsValueLast
STARVDWOLF LLC1$867KAug 28, 2026
BUSINESS RESOURCES OF LONG ISL LOCUST VALLEY 115601$378KJun 23, 2026
SENTINEL SERVICES, LLC1$248KApr 15, 2026
MASS TANK INSPECTION SERVICES LLC1$22KOct 7, 2025

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in. Revenue next to a ticker is the company's last annual revenue from its 10-K.

Latest awards

Competitive landscape

For the 4 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 0 of these past winners lobbied Veterans Affairs, Dept of (VA) since 2024 (0 filings)
  • 0 of their lobbyists list a past Veterans Affairs, Dept of (VA) job
  • No corporate PAC money from them to the overseeing committees since 2024
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 0 bills named on the past winners' lobbying filings
  • 25 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.

  • 0 of the past winners are listed companies
  • 0 insider buys and 0 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.