Combined Synopsis/SolicitationPosted Aug 4, 2026·Responses due Aug 15, 2026

AIRFIELD LEAKING TRANSFORMER

Coast Guard · BASE CAPE COD(00052)

Stage
Open solicitation
NAICS
811310
Value
Not stated
Solicitation
31125260000817
Set-aside
Small Business Set Aside - Total
PSC
J061
Place
Buzzards Bay, MA, USA
Contact
STEVE SIMPSON (STEVEN.M.SIMPSON@USCG.MIL)
Loading your pipeline and notes…
CSV Email

Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.

Where this opportunity stands

Every notice posted under solicitation 31125260000817 in this department, oldest first.

Early notice
None posted
Solicitation
  • Jul 22, 2026
    Combined Synopsis/Solicitation
    Open
  • Aug 4, 2026 · this notice
    Combined Synopsis/Solicitation
  • Aug 4, 2026
    Combined Synopsis/Solicitation
    Open
Award
Not yet. Typical award: Aug 8, 2026 to Aug 26, 2026, middle of the range Aug 16, 2026.
Measured from 11 past solicitations at Us Coast Guard with NAICS 811310 that later posted an award (middle half of cases, counted from Jul 22, 2026).
Responses are due Aug 15, 2026, so an award before then is unlikely; past cases include short solicitations.

Next steps for this stage

Standard steps for the notice type; not advice about this buyer.

  • Decide bid or no bid before the response deadline.
  • Look at the past winners for likely competitors and teaming partners.
  • Follow the opportunity to hear about amendments and the award.

What the notice says

SCOPE: The Contractor shall provide all personnel, equipment, tools, materials, supervision, and other items and services necessary to remove and dispose of existing airfield lighting transformers and replace with new (Fig. 1-11) at the U.S. Coast Guard, Base Cape Cod, on Joint Base Cape Cod, Buzzards Bay, MA, 02542. Existing transformers: Contractors shall verify transformer specifications. Transformer 413 (Fig. 1-3), adjacent to building 614 and runway 23. MANUFACTURER - McGraw Edison, Power System Division, Canonsburg, PA, 15317, single phase, 60 hertz, KVA 37 �, 65� RISE, serial number 74Z… (show all)

D743004, voltage rating 4160GRD.Y/2400x12470GRD.Y/7200x13800GRD.Y/7970 240/120, cat nc. AAVL 115079A-37-K1, class OA, % IMP. 1.9 - 1.8, WDG MAT L.V. AL HV CU, wt.lb. 855, H.V. CONNECTION: VOLTAGE 2400 � SWITCH POSITION 2.4, VOLTAGE 7200 � SWITCH POSITION 7.2, VOLTAGE 7970 � SWITCH POSITION 7.9 Transformer 523 (Fig. 4-6), adjacent to building 614 and runway 14, MANUFACTURER - McGraw Edison, Power System Division, Canonsburg, PA, 15317, single phase, 60 hertz, KVA 37 �, 65� rise, serial number 73ZE858030, voltage rating 4160GRD.Y/2400x12470GRD.Y/7200x13800GRD.Y/7970 240/120, cat nc. AAVL 115079A-37-K1, class OA, % imp. 1.9 - 1.8, WDG MAT L.V. AL HV CU, wt.lb. 855, H.V. CONNECTION: VOLTAGE 2400 � SWITCH POSITION 2.4, VOLTAGE 7200 � SWITCH POSITION 7.2, VOLTAGE 7970 � SWITCH POSITION 7.9 Transformer 232177 (Fig. 7-9), adjacent to building 3181 parking. MANUFACTURER - ABB, Power System Division, Jefferson City, MD, 21755, Three phase distribution, 60 hertz, KVA 1500/1680, 55/65� RISE, style number F3HF147L66, serial number 11JC572250001, MFG Date Jun-11, voltage rating 22860GRDy13200, HV BIL KV 125, HV MTL AL, % Impedance 5.75, Low voltage 4160Y/2400, LV BIL KC 60, LV MTL AL, Mineral Oil 513 Gallons. NOTE: The Contractor shall investigate and determine the existence of oil leaks and provide analysis/feasibility for replacement or repair. Option Bid: Transformer 575 (Fig. 10-12), adjacent to building 195 and runway 5, Manufacturer Southeastern Transformer Co, Dunn, NC, single phase, 60 hertz, KVA 15, % imp. 3.6, serial number 1019102, volts 12470GRDY/7200-240/120. Updated Section: We discovered an issue with the Transformer replacement Statement of Work (SOW). There are two transformers that service building 3181 the wrong transformer is identified on in SOW. Statement of Work 1.1.1 transformer 3) description �Transformer 232177 (Fig. 7-9), adjacent to building 3181 parking. MANUFACTURER - ABB, Power System Division, Jefferson City, MD, 21755, Three phase distribution, 60 hertz, KVA 1500/1680, 55/65� RISE, style number F3HF147L66, serial number 11JC572250001, MFG Date Jun-11, voltage rating 22860GRDy13200, HV BIL KV 125, HV MTL AL, % Impedance 5.75, Low voltage 4160Y/2400, LV BIL KC 60, LV MTL AL, Mineral Oil 513 Gallons. NOTE: The Contractor shall investigate and determine the existence of oil leaks and provide analysis/feasibility for replacement or repair.� Transformer 3) description SHOULD read � Transformer 138613, adjacent to building 3181 apron, Manufacturer -ABB, Power System Division, Jefferson City, MD , 21755, 3 phase distribution, 60 hertz, KVA 1000/1120, 55/65�, style number F25E017L67, serial 11JC573270001, MFG Date July 11, voltage rating 4160GRDY/2400, HV AL, Impedance 5.80, low voltage 480Y/277, LV 30, mineral oil 329 gallons. SEE UPDATED SOW FOR FULL REQUIREMENTS

Who won similar work

4 award notices on SAM.gov in the last 24 months. Matched by: Same agency (Coast Guard), same product/service code (PSC) J061.

Single-winner award sizes (4): middle half $18K to $67K, median $27K; range $7K to $171K.

WinnerAwardsValueLast
AG'S SERVICES, LLC1$171KJul 8, 2026
ORE POWER LLC1$33KAug 25, 2026
GUARDIAN SYSTEMS LLC1$21KJun 8, 2026
Titan Specialized Services Inc.1$7KJul 17, 2025

Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in. Revenue next to a ticker is the company's last annual revenue from its 10-K.

Latest awards

Competitive landscape

For the 4 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.

  • 0 of these past winners lobbied U.S. Coast Guard (USCG) since 2024 (0 filings)
  • 0 of their lobbyists list a past U.S. Coast Guard (USCG) job
  • No corporate PAC money from them to the overseeing committees since 2024
  • 0 foreign-agent (FARA) registrations
See who and the source records with Pro

Policy around it

Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.

  • 0 bills named on the past winners' lobbying filings
  • 433 rules from the department in the last 12 months
  • 0 executive orders naming the agency in the last 12 months
See who and the source records with Pro

Market

For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards. A sale marked 10b5-1 was made under a trading plan set up in advance.

  • 0 of the past winners are listed companies
  • 0 insider buys and 0 insider sells at them in the last 90 days
See who and the source records with Pro

Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.

Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.