Bldg. 1025 HVAC at Kirtland AFB
Army Corps of Engineers · W075 ENDIST ALBUQUERQUE
Capture briefs (a one-page, shareable copy of this page) are part of Pro. The CSV here holds the notice, its timeline and past awards.
Where this opportunity stands
Every notice posted under solicitation W912PP26QA045 in this department, oldest first.
- Sep 29, 2026 · this noticeAward NoticeCOLT BUILDERS INC · $207K
Next steps for this stage
Standard steps for the notice type; not advice about this buyer.
- Note the winner and the end of the period of performance for the recompete.
- Follow the agency to see the next notice for this work.
What the notice says
This action was awarded as an 8(a) Sole Source Set-Aside under the authority of section 8(a) of the Small Business Act. The contractor shall furnish all parts, material, labor, equipment and supervision necessary to complete the work for Building 1025 HVAC. Construction Contractor to provide and install an 8.5�x20.5� duct hood over the air compressor heat exhausts that transition to 14� � round duct. Duct hood must be detachable to allow for the removal of the compressor top plate for maintenance. Contractor to remove SF-1 and wall louver. Expand existing 12�x18� wall penetration to 18�x18� pe… (show all)
netration on the South wall. Install wall mounted exhaust fan rated for 1500 CFM @ 1� W.C. with using single phase 208V with soft start motor. Fan and motor must be rated to handle 140�F exhaust air. Provide 18�x18� ducted exhaust plenum 2� into the mechanical room. Route 14�� duct from each compressor into the 18�x18� plenum. Utilize conical fittings for branch take-offs and 30� minimum rectangular to round transitions and 1.5D round elbows. Provide gasketed low leakage motorized control dampers on each 14�� duct between the hood and the exhaust plenum. Contractor to provide a 3-ton (36,000 BTU/hr) wall mounted mini split air conditioning unit on west wall above the compressed air desiccant driers. Mount wall mounted unit on available space without moving existing compressed air piping or conduit. Secure unit to wall per manufacturer instructions. Route condensate to nearest floor sink. Terminate condensate pipe above floor sink rim. Size per manufacturer requirements. Contractor to provide mini split condensing unit with high ambient kit by the same manufacturer. Locate exterior unit between stairs to electrical room and mechanical room. Secure unit to the ground per manufacturer instructions or mounted on C-channel with concrete anchors. Mini split must be 208V single phase. Contractor to provide and install refrigerant line sets between mini split per manufacturer instructions. Flash and seal new penetration for line set. Provide controls for equipment as follows: Exhaust fan must start when either compressor activates. Fan must remain on for at least 5 minutes (adjustable up to at least 15 minutes) after compressor turns off. Motorized control dampers must open when associated air compressor is activated. Damper must stay open until the exhaust fan turns off. Provide duct access panel for each damper on the bottom of the duct. Provide thermostat for new mini split. Set temperature to 85�F (adjustable). All new duct and duct connections shall be sealed to Class A and hung from the structure or mechanical room walls (where allowed) per SMACNA HVAC Duct Construction Standards. Provide 1in. W.C. Duct Pressure Classification on all exhaust duct systems, provide a minimum 22 Ga. Galvanized sheet metal meeting ASTM A924/A924M and ASTM A653/653M for all exhaust duct as indicated on the supplemental drawings. Provide power to the new exhaust fan and motorized control dampers from Panel P1. Reuse of conduit from demolished supply fan is acceptable provided it meets all NEC requirements. Provide power to mini split air conditioner from panel LM1. All wiring must be provided per NEC. Provide disconnects to exhaust fan, condensing unit and indoor unit per UFC 3-410-01. Contractor will need to be escorted at all times with the construction schedule coordinated with the facility user. All new penetrations between the electrical and mechanical rooms must be sealed with fire caulk. The North and East walls in the Mechanical Room cannot have any new penetration or be utilized to mount hang or hang any new equipment.
Who won similar work
5 award notices on SAM.gov in the last 24 months. Match: Same office, same NAICS 238220.
| Winner | Awards | Value | Last |
|---|---|---|---|
| ALPHA DEVELOPMENT INC. | 2 | $4.3M | Sep 22, 2026 |
| FOUR WINDS MECHANICAL HTC/AC INC. | 2 | $193K | Sep 29, 2025 |
| ACCESS COMMUNICATIONS GROUP, LLC | 1 | $4.2M | Jun 30, 2026 |
Value counts single-winner awards. "Shared" awards are multiple-award contracts that list every winner with the same total ceiling; that ceiling is not one company's win, so it is not added in.
- Sep 22, 2026ALPHA DEVELOPMENT INC.$261KSanta Rosa HVAC & Power Stabilization Upgrade
- Jun 30, 2026ACCESS COMMUNICATIONS GROUP, LLC$4.2MBldg. 1870 HVAC Upgrades and Repairs, WSMR
- Sep 29, 2025FOUR WINDS MECHANICAL HTC/AC INC.$76KW912PP25PA023 Replace Mini-Splits at Abiquiu Dam, Rio Arriba, New Mexico
- Sep 28, 2025ALPHA DEVELOPMENT INC.$4.0MHVAC Repairs, B-22840 N300, WSMR
- Aug 25, 2025FOUR WINDS MECHANICAL HTC/AC INC.$116KCH HVAC Replacement
Competitive landscape
For the 3 most frequent past winners above. Lobbying is matched by the company's exact name or exact ticker; agencies are as named on the filings.
- 0 of these past winners lobbied Army, Dept of (Corps of Engineers) or Army, Dept of (Other) or Natl Guard since 2024 (0 filings)
- 0 of their lobbyists list a past Army, Dept of (Corps of Engineers) or Army, Dept of (Other) or Natl Guard job
- No corporate PAC money from them to the overseeing committees since 2024
- 0 foreign-agent (FARA) registrations
Policy around it
Bills the past winners named while lobbying this agency's issues, rules from the department, and executive orders that name the agency, last 12 months.
- 0 bills named on the past winners' lobbying filings
- 32 rules from the department in the last 12 months
- 0 executive orders naming the agency in the last 12 months
Market
For past winners matched exactly to a listed company. Insider trades are open-market buys and sells (Form 4) in the last 90 days, shown as facts; our own study found insiders do not reliably buy ahead of awards.
- 0 of the past winners are listed companies
- 0 insider buys and 0 insider sells at them in the last 90 days
Sources: SAM.gov notices and award notices; Senate LDA lobbying filings; FEC filings; FARA; Federal Register; congress.gov; SEC Form 4. Every row above links to its record.
Companies are matched to tickers by exact name only. A company we could not match shows no market rows; that is a miss, not a finding.